The application software provides input data by, for example, converting the IRIS standard
cartesian MLHGT products to the curved Earth coordinates of the sweeps configured for the
radar task. Typically, a map for a collection of sweeps (a volume) is uploaded.
The application software adjusts the spatial resolution of the map by down scaling of gates
so that it fits in the buffer managed in RDA:
DPOLAPP_MAX_ML_SWEEPS*DPOLAPP_MAX_ML_RAYS*DPO LAPP_MAX_ML_BINS
The command also checks the maximum number of sweeps and rays
(
DPOLAPP_MAX_ML_SWEEPS = 30
and
DPOLAPP_MAX_ML_RAYS=90
). If the buffer
does not exist or exceeds its limits, it is flushed.
RVP900 supports a command that provides a way to feedback the melting layer
information from IRIS to the RDA. The melting layer altitude information is specified for each
antenna angle and range. This way, the melting layer height can be used in different live data
processing applications such as
HydroClass
.
RVP900 maintains an internal array of up to 1024 different filter versus- range tables, each
of which is keyed to a particular angle (
EL
, for PPIs and
AZ
for RHIs). Each
XOP_MLSPEC
command uploads the complete sweep. Then, for each live bin in every processed ray
processed, RVP900 obtains the melting layer at the midpoint
AZ
/
EL
of the ray.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Scan Type (Unsigned 16-bit integer) | XARG 1
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Number of sweeps (Unsigned 16-bit integer) | XARG 2
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Number of rays (Unsigned 16-bit integer) | XARG 3
|----------------------------------------------------------------|
Chapter 8 – Host Computer Commands
325
Содержание RVP900
Страница 1: ...M211322EN J User Guide RVP900 Digital Receiver and Signal Processor RVP900...
Страница 19: ...RVP9IFD China RoHS Compliance RVP901 AC and RCP903 China RoHS Compliance Chapter 2 Product Overview 17...
Страница 22: ...RVP900 User Guide M211322EN J 20...
Страница 88: ...RVP900 User Guide M211322EN J 86...
Страница 170: ...RVP900 User Guide M211322EN J 168...
Страница 236: ...RVP900 User Guide M211322EN J 234...
Страница 390: ...RVP900 User Guide M211322EN J 388...
Страница 434: ...Figure 68 ASR9 WSP with RVP7 Architecture RVP900 User Guide M211322EN J 432...
Страница 456: ...Figure 82 J90 to J111 Wiring Diagrams RVP900 User Guide M211322EN J 454...
Страница 457: ...Figure 83 J13 Wiring Diagram Appendix H TDWR Customizations 455...
Страница 468: ...RVP900 User Guide M211322EN J 466...
Страница 482: ...RVP900 User Guide M211322EN J 480...
Страница 483: ......
Страница 484: ...www vaisala com...