Figure 67 Ascope Differences during RVP900 TS Playback
When RVP900 is in playback mode, instead of processing real-time data, the major
difference is that some parameters were fixed at the time, when the data were recorded.
Some examples of fixed parameters are:
• Maximum range
• PRF
• Transmit polarization
• Number of range bins
• Phase coding
• Value of noise level
These parameters relate to the transmit characteristics of the radar and for these, the
archived value is displayed. You cannot alter the fields.
There are other parameter fields that can be changed, just like when you use
Ascope
with
real-time data, such as the parameters to configure processing and plotting. For example,
you can change processing major mode and clutter filtering parameters while RVP900 is in
playback mode.
When using
Ascope
during RVP900 playback, the archive can be on the local RVP900 or on
a separate archive host.
It does not matter where
Ascope
runs. It can be on the local RVP900 or on a networked
host computer through
DspExport
.
Appendix D – Time Series Recording
407
Содержание RVP900
Страница 1: ...M211322EN J User Guide RVP900 Digital Receiver and Signal Processor RVP900...
Страница 19: ...RVP9IFD China RoHS Compliance RVP901 AC and RCP903 China RoHS Compliance Chapter 2 Product Overview 17...
Страница 22: ...RVP900 User Guide M211322EN J 20...
Страница 88: ...RVP900 User Guide M211322EN J 86...
Страница 170: ...RVP900 User Guide M211322EN J 168...
Страница 236: ...RVP900 User Guide M211322EN J 234...
Страница 390: ...RVP900 User Guide M211322EN J 388...
Страница 434: ...Figure 68 ASR9 WSP with RVP7 Architecture RVP900 User Guide M211322EN J 432...
Страница 456: ...Figure 82 J90 to J111 Wiring Diagrams RVP900 User Guide M211322EN J 454...
Страница 457: ...Figure 83 J13 Wiring Diagram Appendix H TDWR Customizations 455...
Страница 468: ...RVP900 User Guide M211322EN J 466...
Страница 482: ...RVP900 User Guide M211322EN J 480...
Страница 483: ......
Страница 484: ...www vaisala com...