Installation
8
Installation instructions for the electronicVED exclusive electric instantaneous water heater 0020176440_00
4
4.3
Required minimum clearances
D
E
B
B
C
A
C
4.2 Installation clearances
Key
A At least 50 mm
B At least 50 mm
C At least 120 mm
D At least 130 mm
E Maximum 22 mm
The bottom section of the unit (
D
) must be level with the
unit's bearing area on the wall; to a height of at least
130 mm. Any possible wall offset (e.g. due to tiles) must not
exceed 22 mm (
E
). The distance to the floor must be at
least 120 mm (
C
). The distance above, to the left and to the
right of the unit must be at least 50 mm.
4.4
Mounting the unit to the wall
4.4.1 Unit
and
connection
dimensions
240
100
70
50
277
481
322
5
16
19
99
R 1/2
35
35
1
2
3
5
6
4
4.3 Boiler dimensions
Key
1 Upper anti-spray-water sleeve
2 Central
attachment
3 Display
4 Hot water connection R 1/2
5 Cold water connection R 1/2
6 Lower anti-spray-water sleeve
R Outside thread R 1/2
390
322
85
85
1
1
2
3
4.4 Connection dimensions
Key
1 Installation
plate
2 Cold water connection
3 Hot water connection