Installation
Installation instructions for the electronicVED exclusive electric instantaneous water heater 0020176440_00
13
4
4.6.3 Optional load-shedding relay
If required, a load-shedding relay that conforms with cur-
rent standards can be connected to the electronicVED
exclusive. This relay will turn other power consumers off
while hot water is being drawn off so that there is no over-
loading. The load-shedding relay must fulfil the following
criteria:
– Input current < 15 A
– Continuous current > 50 A
>
Install the optional load-shedding relay to the outer con-
ductor that is connected to the L2 mains connection ter-
minal of the electronicVED exclusive.