Operating Manual geoTHERM VWS/VWW 0020051578_01
20
Display shown
Description
Factory setting
Holiday programming
6
for cpl. System
Period of
time
1
>06.01.08
08.01.08
2
14.01.08
30.01.08
Room Temp. setpoint
12 °C
>Set start day
For the controller and its connected system compo-
nents it is possible to programme two holiday peri-
ods with the introduction of the date. Moreover, the
desired target room temperature can be set for holi-
days, i.e. regardless of the preset timer programme.
After the holiday time has elapsed, the controller
automatically goes back to the previously selected
operating mode. The holiday program can be acti-
vated only in auto and eco operating mode.
Connected cylinder charging circuits or circulation
pump circuits are automatically switched to OFF
operating mode during the holiday time program.
Connected cylinder charging circuits or circulation
pump circuits are automatically switched to OFF
operating mode during the holiday time program.
Prolonged periods of absence can be set in the dis-
play "Programme holidays". The target temperature
during this period should be selected to be as low as
possible.
During this period hot water generation is not in
operation.
Period 1:
01.01.2003 –
01.01.2003
Period 2:
01.01.2003 –
01.01.2003
Room Temp. set-
point 15 °C
Basic data
7
Date
21.04.08
Day of
week
Mo
Time
09:35
>Settable values
You can set the current
date
, the
day of the week
and the current
time
, if DCF radio clock reception is
not possible, in the
"Basic Data"
menu.
These settings apply to all connected system compo-
nents.
Code layer
8
Code number:
> 0 0 0 0
>Set figures
To access the Code level (Installer level), the appro-
priate code must be entered.
To view setting parameters without entering the
code, you must press the dial once. You can then
view all parameters of the code level by turning
the dial but not change them. As operator, without
entering the code, you can view all menus in the
code level however not modify them.
Caution! Do not try to access the code level by
making arbitrary entries in the code level. Uninten-
tional modification of the system-specific parame-
ters can cause malfunctions or damage to the heat
pump.
Table 5.1 Settable parameters in the operator level (contd.)
5 Operation
Содержание geoTHERM VWS
Страница 1: ...geoTHERM VWS VWW GB ES ...
Страница 2: ......
Страница 3: ...For the owner Operating manual geoTHERM VWS VWW Heat pump GB ...
Страница 34: ......
Страница 35: ...Para el usuario Instrucciones de uso geoTHERM VWS VWW Bomba de calor ES ...
Страница 66: ......
Страница 67: ......
Страница 68: ...0020051578_01 GBES 032009 Subject to alterations Reservado el derecho a introducir modificaciones ...