23
Operating Manual geoTHERM VWS/VWW 0020051578_01
5.7
Starting up the heat pump
The start-up of your heat pump was carried out after
installation by your expert technician company.
Your heat pump does not need to be started up again if
it disconnects from the mains unexpectedly, for example
as a result of a voltage drop (power cut, circuit breaker
defective, circuit breaker deactivated). Your geoTHERM
heat pump has an automatic reset function, i.e. the heat
pump reverts automatically to its starting condition,
provided no fault is present in the heat pump itself. Find
out what to do in the event of a fault in Chap. 5.12.
5.8
Shutting down the heat pump
The heat pump can only be switched off via the opera-
tor control panel by deactivating the heating and hot
water generation (operating mode "Off").
<HK2>
2
Parameters
Operating mode heating
>Off
Set value day
22 °C
Night set back temp.
15 °C
>Select operating mode
Fig. 5.3 Switching off the heating mode
DHW loading
4
Parameters
Operating mode WW
>Off
Max. DHW temp.
60 °C
60 °C
Min. DHW temp.
44 °C
44 °C
Cylinder temp. REAL
51 °C
51 °C
>Select set target temperature
Fig. 5.4 Switching off the hot water generation
h
Deactivate the fuse on your heating sys-
tem if you need to de-energise the heat
pump installation completely.
5.9
Inspection by a specialist engineer
In contrast to heaters based on fossil fuels, no expen-
sive maintenance work is necessary for the Vaillant geo-
THERM heat pump. However an annual inspection of the
system by a specialist is a prerequisite for continued
operational safety, reliability and a long working life.
d
Danger!
If inspections are not carried out, this
can result in damage to property and
personal injury.
Only have inspections and repairs car-
ried out by an approved heating installa-
tion company.
h
Note Have your system checked regular-
ly by an expert technician company to
ensure efficient operation of your heat
pump.
5.10
Inspection by the operator
In addition to the annual inspection by an expert, a
small amount of inspection work needs to be carried out
by the operator.
5.10.1 Checking the filling pressure of the heating
system
The filling pressure of the heating installation should be
checked at regular intervals.
Mon. 21.04.08
16:49
1
Current flow temp.
28 °C
CH pressure
1.2 bar
Brine pressure
1.4 bar
Heating only comp.
Warning message
Warning message
Fig. 5.5 Check filling pressure
• Read off the filling pressure of your heating installa-
tion at the heat pump controller (see Fig. 5.5).
The pressure in the heating installation should be be-
tween 1 and 2 bar. If it falls below 0.5 bar, the heat pump
will be shut down automatically and an error message
will be displayed.
Operation 5
GB
Содержание geoTHERM VWS
Страница 1: ...geoTHERM VWS VWW GB ES ...
Страница 2: ......
Страница 3: ...For the owner Operating manual geoTHERM VWS VWW Heat pump GB ...
Страница 34: ......
Страница 35: ...Para el usuario Instrucciones de uso geoTHERM VWS VWW Bomba de calor ES ...
Страница 66: ......
Страница 67: ......
Страница 68: ...0020051578_01 GBES 032009 Subject to alterations Reservado el derecho a introducir modificaciones ...