Troubleshooting
Instructions for installation and servicing ecoTEC 839592_13
61
8
Display
Meaning
Heating mode (all models):
S. 0
No heat demand
S. 1
Fan running
S. 2
Water pump running
S. 3
Ignition sequence
S. 4
Burner ignited
S. 5
Fan and pump running
S. 6
Fan over run
S. 7
Pump over run
S. 8
Anti cycling mode
Domestic hot water mode (ecoTEC combination boilers only):
S.10
Hot water demand
S.11
Fan running
S.13
Ignition sequence
S.14
Burner ignited
S.15
Fan and pump running
S.16
Fan over run
S.17
Pump over run
Warm start (ecoTEC combination boilers only) / Charge hot
water cylinder (ecoTEC system boilers only):
S.20
Warmstart demand
S.21
Fan running
S.22
Pump running
S.23
Ignition sequence
S.24
Burner ignited
S.25
Fan and water pump running
S.26
Fan over run
S.27
Pump over run
S.28
Anti cycling mode
All boilers:
S.30
No heating demand from external controls (clamp 3-4 open)
S.31
Central heating thermostat knob turned off or no heat
demand by the eBUS control unit
S.32
Heat exchanger antifreeze active, as fan speed
variation is too high. Appliance is within the waiting
time of the operation block function
S.34
Antifrost mode active
S.36
No heating demand from low voltage controls (clamp 7-8-9)
S.41
Water pressure > (2.9 bar) 0.29 MPa
S.42
Response from accessory modul or defective
condensate pump is blocking burner operation
S.52
Water pressure > (2.9 bar) 0.29 MPa
S.53
Appliance is within the waiting period of the operation
block function due to water shortage (VL-RL spread too
big)
S.54
Appliance is within the waiting period of the operation
block function due to water shortage (temperature gra-
dient)
S.96
Return-sensor check is running, demand (DHW or
heating) is blocked
S.97
Water pressure sensor check is running, demand (DHW
or heating) is blocked
S.98
Flow-/Return-sensor check is running, demand (DHW or
heating) is blocked
Table 8.1 Status codes (continued)
8.1.2 Diagnostic
codes
In the diagnostic mode, you can change certain
parameters or display more information.
The diagnostic information is divided into two diagnostic
levels. The second diagnostic level can be reached only
after entering a password.
b
Caution!
Possible material damage caused by impro-
per handling!
Improper settings in the 2nd diagnostic level
may cause damage to the heating system.
>
The 2nd diagnostic level should only be
accessed if you are a recognised specia-
lised technician with Health and Safety
Executive approval.
First Diagnostic level
>
Press the “
i
” and “
+
” keys simultaneously.
The display shows “
d.0
”.
>
Use the “
+
” or “
–
” keys to scroll through the desired
diagnostic numbers of the first diagnostic level (see
Table 8.2).
>
Press the “
i
” key.
The display shows the relevant diagnostic information.
>
If necessary, use the “
+
” or “
–
” keys to change the
value (display flashes).
>
Save the new value by holding down the “
i
” key for
approx. 5 seconds until the display no longer flashes.
You can end the diagnostic mode as follows:
>
Press the “
i
” and “
+
” keys simultaneously.
or
>
Do not press any key for approx. 4 minutes.
The current heating flow temperature appears in the dis-
play again.