General requirements
14
Instructions for installation and servicing ecoTEC 839592_13
3
bar
i
F
P
1
2
3
7
6
5
4
Fig. 3.3 Contents included with delivery of ecoTEC pro combi-
nation boilers
DO NOT remove the boiler from the polystyrene base at
this stage.
Item
Quantity Description
1
1
Hanging bracket
2
1
Boiler
3
2
Connecting pipes (hot water, heating safety
valve)
4
4
Isolating valves
5
1
Template
6
1
User, installation and service and flue installa-
tion manuals
7
2
Installation and connection accessories
Table 3.3 Contents included with delivery of ecoTEC pro combi-
nation boilers
3.4 Installation
site
The location chosen for the boiler must permit the provi-
sion of a satisfactory flue termination. The location must
also provide adequate space for servicing and air circu-
lation around the boiler. The boiler may be installed in
any room, although particular attention is drawn to the
requirements of BS 7671 (IEE Regulations), the electrical
provisions of the Building Standards (Scotland) Regula-
tions, and in IE the current edition of IS 813 and the cur-
rent ETCI rules, in respect of the installation of a boiler
in a room containing a bath or shower.
e
Danger!
Risk of death from electric shock when
installing an appliance that is independent
of ambient room air in a room with a bath
or shower!
If electric switches and controls are installed
too close to a bath or shower, there is a risk
of electric shock for the person using the
facility.
>
Install electric switches and controls that
are operated via mains voltage out of reach
of the bath or shower.
i
If the boiler is to be installed in an airing cup-
board it is not required to separate the boiler
with a non-combustible partition. However
installation and servicing clearances must be
maintained, and the appliance kept clear of
any clothing.
If the boiler is installed in an unusual location, special
procedures may be necessary and BS 5546 and BS 6798
give detailed guidance on this aspect. The boiler must be
mounted on a flat, vertical wall, which must be
sufficiently robust to take the weight of the boiler. The
boiler may be installed on a combustible wall, subject to
the requirements of the Local Authorities and Building
Regulations. Details of essential features of cupboard/
compartment design including airing cupboard
installations are given in BS 6798. If the boiler is to be
fitted in a timber framed building, it should be fitted in
accordance with Institute of Gas Engineers Publication
“IGE/UP/7 Edition 2 Gas installations in timber framed
and ligh steel framed buildings“. Note the safety
instructions below before deciding where to install the
boiler:
b
Caution!
Possible material damage due to an unsuit-
able installation site!
The appliance may be damaged by frost,
aggressive vapours or dust.
>
Do not install the appliance in rooms that
are susceptible to frost.
>
Do not operate the unit in rooms with
aggressive vapours or dust unless it is
operated in a way that does not depend on
the room air.
When choosing the place of installation and while
operating the appliance, make sure that the air supply is
free of chemical substances containing fluorine, chlorine,
sulphur etc. Sprays, solvents and cleaning agents, paints,