ecoTEC plus 937 installation and maintenance manual
6
2
Unit description, data and
dimensions
2.1 Technical
data
Name
ecoTEC plus 937
Combination unit
Unit
Nominal heat output range of central heating
80 °C Feed/60 °C Return
60 °C Feed/40 °C Return
50 °C Feed/30 °C Return
40 °C Feed/30 °C Return
12.0 - 28.0
12.3 - 28.9
12.7 - 29.7
12.9 - 30.3
kW
kW
kW
kW
Maximum output DHW
37
kW
Maximum heating output
28
kW
Minimum output
12
kW
Category
II2H3P
SEDBUK Band
A
SAP Seasonal Efficiency
91.5
%
Required gas flow pressure (G20, Natural Gas)
20
mbar
Required gas flow pressure (G31, Propane)
37
mbar
Connection value (if necessary referred to storage tank charging/hot water preparation) at
15 °C and 1013 mbar
G20: 4.0
G31 : 2.94
G20 :m
3
/h
G31 : kg/h
Exhaust mass flow
at minimum thermal load (40 °C Feed/30 °C Return)
at maximum thermal load (80 °C Feed/60 °C Return)
5.7
17.1
g/s
g/s
Exhaust temperature
at minimum thermal load (40 °C Feed/30 °C Return)
at maximum thermal load (80 °C Feed/60 °C Return)
40
70
°C
°C
NOx class
5
Protection class
IP X4D
Max. flow temperature
85
°C
Adjustable flow temperature (default setting: max. 75 °C)
30 - 85
°C
Permissible total excess pressure central heating
3.0
bar
Volume of water circulating (
Δ
T =20 K)
1204
l/h
Approximating condensation water volume at 50 °C Feed/30 °C Return
2.9
l/hr
Pump head
250
mbar
Minimum water flow
< 0.1
l/min
Specific throughflow in 10 min (
Δ
T = 30 K)
204
l/10min
Permissible excess pressure water side
10
bar
Required connection pressure for max. throughflow quantity
1.3
bar
Required connection pressure for min. throughflow quantity
0.1
bar
Hot water temperature discharge
35 - 65
°C
Flue size (concentric)
60/100
mm
Flue approval category
C
13
, C
33
, C
43
, C
53
, C
83
, B
23
, B
33
Pre-pressure 10 l expansion vessel
0.75
bar
Connections for heating flow and return
22
mm
Gas connection
22
mm
Diameter of the drain line for the safety valve heating (min.)
15
mm
Diameter of the drain line for the safety valve hot water (min.)
15
mm
Condensate drain (min. internal diameter drain)
19
mm
Dimensions (H x W x D)
720 x 440 x 597
mm
Primary water quantity
2.5
l
Supply voltage
230/50
V ~/Hz
Main PCB fuse (slow-blow) for main power supply
2
A
Electr. Power consumption
175
W
Standby power consumption
6.5
W
Shift load power store capacity
15
l
Installation weight, just storage tank
17
kg
Installation weight, just combi unit
38
kg
Operating weight (with water)
62
kg
Table 2.1 Technical Data ecoTEC plus 937
2 Unit description, data and dimensions