Appendix
0020181589_04 auroCOMPACT Installation and maintenance instructions
57
VSC S 146/4-5 150
(LL)
VSC S 206/4-5 150
(LL)
Maximum heating flow
temperature
80
℃
80
℃
Max. flow temperature ad-
justment range (default
setting: 75 °C)
30 … 80
℃
30 … 80
℃
Maximum permissible
pressure
0.3 MPa
0.3 MPa
Nominal water flow
(
Δ
T = 20 K)
603 l/h
861 l/h
Nominal water flow
(
Δ
T = 30 K)
402 l/h
574 l/h
Approximate value for the
condensate volume (pH
value between 3.5 and 4.0)
at 50/30 °C
1.467 l/h
1.82 l/h
Δ
P heating at nominal flow
(
Δ
T = 30 K)
0.035 MPa
0.029 MPa
Technical data
–
G20 power/loading G20
VSC S 146/4-5 150
VSC S 146/4-5 190
VSC S 206/4-5 150
VSC S 206/4-5 190
Effective output range (P)
at 50/30 °C
3.3 … 15.2 kW
3.3 … 15.2 kW
4.3 … 21.5 kW
4.3 … 21.5 kW
Effective output range (P)
at 80/60 °C
3.0 … 14.0 kW
3.0 … 14.0 kW
3.8 … 20.0 kW
3.8 … 20.0 kW
Hot water heat output
range (P)
3.0 … 16.0 kW
3.0 … 16.0 kW
3.8 … 24.0 kW
3.8 … 24.0 kW
Maximum heat input
–
heating (Q)
14.3 kW
14.3 kW
20.4 kW
20.4 kW
Minimum heat input
–
heat-
ing (Q)
3.2 kW
3.2 kW
4.0 kW
4.0 kW
Maximum heat input
–
hot
water (Q)
16.3 kW
16.3 kW
24.5 kW
24.5 kW
Minimum heat input
–
hot
water (Q)
3.2 kW
3.2 kW
4.0 kW
4.0 kW
VSC S 146/4-5 150
(LL)
VSC S 206/4-5 150
(LL)
Effective output range (P)
at 50/30 °C
3.3 … 15.2 kW
4.3 … 21.5 kW
Effective output range (P)
at 80/60 °C
3.0 … 14.0 kW
3.8 … 20.0 kW
Hot water heat output
range (P)
3.0 … 16.0 kW
3.8 … 24.0 kW
Maximum heat input
–
heating (Q)
14.3 kW
20.4 kW
Minimum heat input
–
heat-
ing (Q)
3.2 kW
4.0 kW
Maximum heat input
–
hot
water (Q)
16.3 kW
24.5 kW
Minimum heat input
–
hot
water (Q)
3.2 kW
4.0 kW
Technical data
–
Power/loading G25
VSC S 146/4-5 150
VSC S 146/4-5 190
VSC S 206/4-5 150
VSC S 206/4-5 190
Effective output range (P)
at 50/30 °C
3.3 … 15.2 kW
3.3 … 15.2 kW
4.3 … 21.5 kW
4.3 … 21.5 kW
Effective output range (P)
at 80/60 °C
3.0 … 14.0 kW
3.0 … 14.0 kW
3.8 … 20.0 kW
3.8 … 20.0 kW
Hot water heat output
range (P)
3.0 … 16.0 kW
3.0 … 16.0 kW
3.8 … 24.0 kW
3.8 … 24.0 kW