5 Installation
16
Installation manual 0020200969_04
5.2.4.3 Installing the roof duct
13
3°
1
336 - 578
120
▶
Insert the air/flue pipe
(1)
without the external collar into
the dormer.
5.2.5
Connecting the product
4
5
3
2
1
6
7
1.
Install the product
(7)
–
see the installation instructions
for the product.
2.
Connect the 87° elbow
(1)
to the connection piece for
the air/flue pipe
(6)
.
3.
Fit the sliding sleeve
(3)
with the sleeve as far as it will
go onto the wall/roof duct
(4)
or the extension
(5)
.
4.
If required, install the extensions.
5.
Connect the sliding sleeve to the 87° elbow.
6.
Install the air clamp
(2)
for the sliding sleeve.
7.
Alternatives 1 / 2
Conditions
: Wall/roof duct without extension
▶
Install the sliding sleeve. (
→
Page 27)
7.
Alternatives 2 / 2
Conditions
: Wall/roof duct with extension
▶
Install the extensions. (
→
Page 28)
▶
Install the 45° elbow. (
→
Page 31)
▶
Install the 87° elbow. (
→
Page 32)
▶
Install the sliding sleeve. (
→
Page 27)
▶
Connect all of the disconnection points with air
clamps. (
→
Page 37)
5.3
Installing the direct, rear, telescopic wall
duct
–
article number 0020228140
5.3.1
Scope of delivery
Ø167
456 - 698
3
4
2
1
1
Telescopic wall duct
2
Wall collar
3
Safety screws (4 pcs)
4
Sealing tape
5.3.2
Determining the pipe length and the
location of the wall duct
120 - 500
Y + 24 - 28
1.
Determine the pipe length (
→
Installation instructions for
the boiler) and define the location of the wall duct.
2.
Measure the clearance Y from the external wall to the
installation surface for the boiler.
3.
Set the required pipe length: Y + 24 mm to 28 mm.
–
If you install the wall collar, add 12 mm to the total
pipe length.
–
If the opening is below a roof projection or a ho-
rizontal surface, you can pull the wall duct up to
500 mm out of the wall in order to guarantee that the
flue gases are extracted without any obstructions.
Note
Do not shorten the telescopic flue pipe.
If the required pipe length cannot be
achieved, use extensions or the horizontal
wall/roof duct.