23
3
12 V
23
4
Fertilizer Motor speed, output (RDC)
BioDrill Motor speed, output (RDS)
Ground
24
1
Rotation Guard, BioDrill Left
Digital In
24
2
24
3
Rotation Guard, BioDrill Left
12 V
24
4
Rotation Guard, BioDrill Left
Ground
25
1
Mini-remote, plus sign
Analogue In
25
2
Mini-remote, seed sign
Digital In
25
3
12 V
25
4
Mini-remote
Ground
WS2 Port
Pin
Function
Type
3
1
BioDrill Motor speed, input (RDC)
Digital In
3
2
3
3
BioDrill Motor speed, input (RDC)
12 V
3
4
BioDrill Motor speed, input (RDC)
Ground
4
1
Seed depth guard sensor, Autopilot
Digital In
4
2
4
3
Seed depth guard sensor, Autopilot
12 V
4
4
Seed depth guard sensor, Autopilot
Ground
12
1
12
2
BioDrill Motor speed, output (RDC)
PWM Out
12
3
12 V
12
4
BioDrill Motor speed, output (RDC)
Ground
14
1
14
2
Autopilot, lift (RDC)
PWM Out
14
3
12 V
14
4
Autopilot, lift(RDC)
Ground
15
1
15
2
Autopilot, lowering (RDC)
PWM Out
15
3
12 V
15
4
Autopilot, lowering (RDC)
Ground
18
1
Tramline BioDrill Right (RDC)
Digital In
18
2
Tramline BioDrill Right (RDC)
Digital Out
18
3
Tramline BioDrill Right (RDC)
12 V
18
4
Tramline BioDrill Right (RDC)
Ground
903099-en-gb; 19.01.2021
39
Содержание E-services
Страница 1: ...903099 en gb 19 01 2021 07 Original instructions Instructions E services Rapid Version 1 6 3 ...
Страница 2: ... Väderstad Holding AB Väderstad Sweden 2018 903099 en gb 19 01 2021 ...
Страница 4: ......
Страница 33: ...Information Figure 11 3 WorkStation 1 outputs Figure 11 4 WorkStation 1 information 903099 en gb 19 01 2021 29 ...
Страница 34: ...Information Figure 11 5 Workstation 2 inputs Figure 11 6 Workstation 2 outputs 30 903099 en gb 19 01 2021 ...
Страница 35: ...Information Figure 11 7 WorkStation 2 information 903099 en gb 19 01 2021 31 ...
Страница 48: ...Where farming starts Väderstad AB SE 590 21 VÄDERSTAD Sweden Phone 46 142 820 00 www vaderstad com ...