12
vacon
X
5
EIP
01
Ethernet IP with
115
VAC / Encoder Interface Option Board
Example 2: Input Assemblies
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
70
0
Running 1 (Fwd)
Faulted
1
2
Speed Actual (low byte)
3
Speed Actual (high byte)
71
0
At Ref
Ref from Net
Ctrl from Net
Ready
Running 2 (Rev)
Running 1 (Fwd)
Warning
Faulted
1
Drive State
2
Speed Actual (low byte)
3
Speed Actual (high byte)
171
0
At Ref
Ref from Net
Ctrl from Net
Ready
Running 2 (Rev)
Running 1 (Fwd)
Warning
Faulted
1
Drive State
2
Speed Actual (low byte)
3
Speed Actual (high byte)
4
FBus Read1 (low byte)
5
FBus Read1 (high byte)
6
FBus Read2 (low byte)
7
FBus Read2 (high byte)
172
0
FBus Read1 (low byte)
1
FBus Read1 (high byte)
2
FBus Read2 (low byte)
3
FBus Read2 (high byte)
181
0
At Ref
Ref from Net
Ctrl from Net
Ready
Running 2 (Rev)
Running 1 (Fwd)
Warning
Faulted
1
Drive State
2
Speed Actual (low byte)
3
Speed Actual (high byte)
4
FBus Read1 (low byte)
5
FBus Read1 (high byte)
6
FBus Read2 (low byte)
7
FBus Read2 (high byte)
8
FBus Read3 (low byte)
9
FBus Read3 (high byte)
10
FBus Read4 (low byte)
11
FBus Read4 (high byte)
12
FBus Read5 (low byte)
13
FBus Read5 (high byte)
182
0
FBus Read1 (low byte)
1
FBus Read1 (high byte)
2
FBus Read2 (low byte)
3
FBus Read2 (high byte)
4
FBus Read3 (low byte)
5
FBus Read3 (high byte)
6
FBus Read4 (low byte)
7
FBus Read4 (high byte)
8
FBus Read5 (low byte)
9
FBus Read5 (high byte)