40 • vacon
service data (sdo)
Tel.+358-(0)201-21
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
8
6046
vl velocity min max
amount
Defines speed limits of the drive in rpm. The parameter
consist of a minimum and a maximum speed.
00
Number of Entries
0x02
0x00
0x02
u8 ro
01
Minimum Speed
0x00000000
0x00000000
0xFFFFFFFF
u32 rw
02
Maximum Speed
0x00000000
0x00000000
0xFFFFFFFF
u32 rw
6048
vl velocity acceleration
This parameter specifies the slope of the acceleration
ramp. The parameter consist of two parts: the delta
speed and the delta time.
v / rpm
delta speed
delta time
t / sec
00
Number of Entries
0x02
0x00
0x02
u8 ro
01
delta_speed
0x00000000
0x00000000
0xFFFFFFFF
u32 rw
02
delta_time
0x0001
0x0000
0xFFFF
u16 rw
6049
vl velocity deceleration
This parameter specifies the slope of the deceleration
ramp. The parameter consist of two parts: the delta
speed and the delta time.
delta speed
delta time
v / rpm
t / sec
00
Number of Entries
0x02
0x00
0x02
u8 ro
01
delta_speed
0x00000000
0x00000000
0xFFFFFFFF
u32 rw
02
delta_time
0x0001
0x0000
0xFFFF
u16 rw
604A
vl velocity quick stop
Not Used
00
Number of Entries
0x02
0x00
0x02
u8 ro
01
delta_speed
0x00000000
0x00000000
0xFFFFFFFF
u32 rw
02
delta_time
0x0001
0x0000
0xFFFF
u16 rw