Standards
The STO function has been designed for being used in accordance with the following standards:
The STO function has to be applied correctly to achieve the desired level of operational safety. Four
different levels are allowed, depending on the use of the STO signals (see the following table).
Table 27. Four different STO levels. (*) see 9.5.1.
The same values are calculated for SIL and SIL CL. According to EN 60204-1, the emergency stop
category is 0.
The SIL value for Safety related system, operating in high demand/continuous mode, is related to
the probability of dangerous failure per hour (PFH), reported in the following table.
Standards
IEC 61508, Parts 1-7
EN 61800-5-2
EN 62061
ISO 13849-1
EN 954-1
IEC 60204-1
Table 26. Safety Standards.
STO inputs
STO feedback
Cat.
PL
SIL
Both dynamically used(*)
Used
4
e
3
Both statically used
Used
3
e
3
Connected in parallel
Used
2
d
2
Connected in parallel
Not used
1
c
1
STO inputs
STO feedback
PFH
PFDav
MTTFd
DCavg
Both dynamically used(*)
Used
1.2 E-09 1/h
1.0 E-04
>4274 a
HIGH
Both statically used
Used
1.2 E-09 1/h
1.1 E-04
>4274 a
MEDIUM
Connected in parallel
Used
1.2 E-09 1/h
1.1 E-04
>4274 a
MEDIUM
Connected in parallel
Not used
1.5 E-09 1/h
1.3 E-04
>4274 a
NONE
Table 28. SIL values. (*) see 9.5.1.
The STO inputs must always be supplied by a safety device.
The power supply of the safety device may be external or taken from the drive (as
long as this is compliant with the rating specified for terminal 6).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание 100X series
Страница 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 14: ...1 vacon 11 Safety Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 26: ...3 vacon 23 Mounting Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 60: ...7 vacon 57 Technical data Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 86: ...8 vacon 83 Options Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 99: ...Safe Torque Off vacon 96 9 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...