Commissioning
vacon • 44
6
6.2
Changing EMC protection class
If your supply network is an IT (impedance-grounded) system but your AC drive is EMC-pro-
tected according to class C1 or C2 you need to modify the EMC protection of the AC drive to
EMC-level T. This is done by removing the EMC screws as described below:
Figure 30. Locations of EMC screws in MM4.
Figure 31. Locations of EMC screws in MM5.
Warning! Do not perform any modifications on the AC drive when it is connected
to mains.
1
Separate the powerhead and the terminal box. Turn the powerhead upside down
and remove the two screws marked in Figure 30 (for MM4), Figure 31 (for MM5)
and in Figure 33(for MM6).