Technical data
vacon • 50
7
7.1.3
Definitions of overloadability
Overloadability
= Following continuous operation at rated output current I
N
, the converter supplies
150% * I
N
for 1 min, followed by a period of at least 9 min at I
N
or below.
Example:
If the duty cycle requires 150% rated current for 1 min in every 10 min, the remaining 9
min must be at rated current I
N
or less.
Figure 34. High overload.
I
N
IN*150%
1 min
9 min
IN*150%
Current
Time