13
INSTALLING & CLEANING CARTRIDGE
FILTER
Installing Cartridge Filter
1. Verify that the power cord is disconnected from the outlet. (Fig. 1)
2. Undo the latches and remove the power head from the collection tank.
3. Place power head on a clean surface in upside down position.
4. Slide the cartridge filter over the filter cage. (Fig. 2) Carefully push filter down until it stops
against the power head. (Fig. 3)
5. Place filter retainer on top of cartridge filter over the raised lip and tighten down by turning
retainer clockwise; do not over-tighten. (Fig. 4)
Removing and Cleaning Cartridge Filter
1. Position power head in the upside down position. If the retainer nut was used to secure the
filter, remove retainer nut by turning counter clockwise.
2. Carefully hold and pull the cartridge filter up for removal. (Fig. 5)
3. Clean the cartridge filter by gently tapping or brushing dirt off. Cleaning should not be done
indoors in living areas. For optimal performance a new filter is recommended.
4. Install cleaned or new filter into place as instructed above.
5. Wet filters should be removed and allowed to air dry for 24 hours before installing onto the filter.
1
2
3
4
5
WARNING:
ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE
REMOVING THE POWER HEAD FROM THE COLLECTION TANK.