Vac - Alert VA-2000 Скачать руководство пользователя страница 17

 

 

Rev 1.06 

  

 

VAC-ALERT FIELD VA-2000 INSTALLATION DATA SHEET 

1-800-374-7405 

 

A copy of this installation form MUST be mailed or faxed to Vac-Alert Industries, LLC within 
10 days of installation to maintain all product warranty. Mail to: Vac-Alert Industries, 336 
West College Ave, Santa Rosa, CA 95401 or fax to (707)-576-8286. 

 

SVRS INFORMATION

 

 

A.

 

Valve ARL serial number:________________________________________________________ 

 

B.

 

Installation performed on:  Pool(  )  Spa(  )  Fountain(  )  Other(  )________________________ 

 

C.

 

Did pool or spa have multiple main drains?  Yes(  )  No(  ) 

 

D.

 

Did valve trip three consecutive times?  Yes(  )  No(  ) 

 

 

INSTALLATION LOCATION INFORMATION

 

 
Name of Purchaser:________________________________________________________________ 
 
Installation Address:_______________________________________________________________ 
 
I have discussed with the owner and/or individual the complete operational and testing procedure 
for the SVRS unit 
 
Installation Performed By:__________________________________________________________ 
 
Date of Installation:________________________________________________________________ 
 

 

Note: Although the SVRS is easily installed, we at Vac-Alert do highly recommend that the unit be 
installed by a Licensed Pool Service Company or an Authorized Service Technician (where State 
required).
 

 

This SVRS does not offer protection from hair entrapment. Please be sure to install recognized 
anti-entrapment drain covers. 

 
 

Содержание VA-2000

Страница 1: ...Safety Vacuum Release System Installation Instructions Model VA 2000 Vac AlertTM Industries LLC 775 8th Court Suite 4 Vero Beach FL 32962 www vac alert com April 29 2011...

Страница 2: ...ation o VAC ALERT MODEL VA 2000S Submerged The Vac AlertTM Model VA 2000S is a Safety Vacuum Release System SVRS designed for submerged suction applications Submerged suction in this case applies to a...

Страница 3: ...s located more than 42 above pool or spa water level contact your Vac AlertTM representative for further instructions For applications where the pump is located more than 24 below pool or spa water le...

Страница 4: ...at each end DO NOT DROP THE UNIT The Installation Instructions DVD and Quick Installation Guide are located in the box stowed between the box and the lower polystyrene insert If the outer package appe...

Страница 5: ...flow coming from the main drain line If the vacuum level is over 15 see previous suggestions for lowering system running vacuum level NOTE Do not use a flow restricted test valve or a slow acting tes...

Страница 6: ...o mount the SVRS off the installed tee A reducing bushing may also be required to mate the 1 1 2 diameter SVRS to the tee fitting installed Utilize pipe nipples to join fittings in a close coupled fas...

Страница 7: ...em Preparation for options on how to lower system operating vacuum level 2 NOTE Each SVRS comes factory set to remain closed non venting for vacuum levels up to 10 Hg If the pump start up test indicat...

Страница 8: ...ion setting is reached then back the adjustment screw off counter clockwise one revolution The adjustment screw must be positioned properly between the two travel stops to set the Vac AlertTM unit for...

Страница 9: ...dry running of self priming pumps where pump suction lift is less than 42 To make sure the unit is working properly turn off the pump and place the Vac AlertTM SVRS unit in the open venting position W...

Страница 10: ...valve is an optional alternative to a pole mounted test mat Each Vac AlertTM SVRS unit must be tested three 3 times to ensure proper adjustment and operation Where a hydro static valve is present the...

Страница 11: ...ain drain blockage b Using the installed test valve or a pole mounted test mat conduct routine testing of the SVRS device to ensure proper adjustment of the unit The Vac AlertTM Model VA 2000 SVRS uni...

Страница 12: ...s operate in a dry state Any indication that the unit is flooded or water logged as evidenced by water leakage from the SVRS unit requires immediate service attention Immediately shut down the pool or...

Страница 13: ...14...

Страница 14: ...l m m m m l l l l m m m l l...

Страница 15: ...l l l...

Страница 16: ...sceration Under no circumstances should any child ever be left unattended at or by any body of water Never sit lay or swim near or by suction ports suction ttings or main drains THIS PRODUCT IS 3RD PA...

Страница 17: ...ION LOCATION INFORMATION Name of Purchaser ________________________________________________________________ Installation Address _______________________________________________________________ I have...

Отзывы: