Vac - Alert VA-2000 Скачать руководство пользователя страница 16

V

AC

-ALER

T™ INDUSTRIES, LLC

AS

SURANCE OF QU

ALITY

Dear V

ac-Alert Safety System Owner

,

   

   

   

   

   

 Y

our 

new 

Vac-Alert 

System 

has 

passed 

rigorous 

quality 

control 

procedure 

and 

is 

in 

conformance 

with 

the 

ASME/ANSI 

A1

12.19.17 

and 

ASTM 

F2387 

standards 

for 

manufactured 

Safety 

Vacuum 

Release 

Systems 

(SVRS). 

If 

you 

feel 

this 

unit 

is 

defective 

or 

damaged 

due 

to 

shipping 

or 

handling, 

it 

is 

your 

obligation 

to 

call: 

1-800-374-7405 

and 

speak 

to 

our 

technical 

support 

staf

to 

answer 

any 

questions 

you 

may 

have. 

This 

system 

requires 

NO 

lubrication 

whatsoever

. Lubricating 

this 

unit 

may 

cause 

failure 

and 

will 

void 

warranty

. V

ac-Alert 

assumes 

no 

liability 

or 

responsibility 

implied 

or 

otherwise 

if 

this 

system 

is 

lubricated. 

W

highly 

recommend 

the 

use 

of 

an 

ASME/ANSI 

A1

12.19.8 

approved 

main 

drain 

cover 

in 

conjunction 

with 

this 

system. 

This 

system 

is 

not 

an 

ef

fective 

defense 

against 

hair 

entanglement. 

This

 devise 

may 

mitigate 

evisceration. 

Under 

no 

circumstances 

should 

any 

child 

ever 

be 

left 

unattended at or by any body of water

. Never sit, lay or swim near or by suction ports, suction fi

ttings or main drains.

THIS PRODUCT IS 3RD P

AR

TY TESTED TO CONFORM TO 

ASME/ANSI A112.19.17 AND ASTM F2387 ST

AND

ARDS

___________________________________

Date of Installation

This unit is warranted fr

ee of defects for a period of thr

ee years. This warranty applies to original pur

chaser only

. This unit will be r

epair

ed or 

replaced at the discr

etion of V

ac-Alert™ Industries, LLC, pr

ovided it is r

eturned to the Manufactur

er Fr

eight-Pr

epaid.

Please keep this document with your other important papers

Vac-Alert™ Industries assumes no liability or r

esponsibility if this unit is installed impr

operly or alter

ed. W

e r

ecommend this system be 

installed by a pool/spa pr

ofessional.

Installed by:______________________   Date:____________________

Installer ID( if applicable)_____________________________________

 

Vac-Alert Unit Serial #

________________________________________

Vac-Alert™ Industries, LLC

www

.vac-alert.com

1-800-374-7405(toll fr

ee)

707-576-8286 (fax)

Содержание VA-2000

Страница 1: ...Safety Vacuum Release System Installation Instructions Model VA 2000 Vac AlertTM Industries LLC 775 8th Court Suite 4 Vero Beach FL 32962 www vac alert com April 29 2011...

Страница 2: ...ation o VAC ALERT MODEL VA 2000S Submerged The Vac AlertTM Model VA 2000S is a Safety Vacuum Release System SVRS designed for submerged suction applications Submerged suction in this case applies to a...

Страница 3: ...s located more than 42 above pool or spa water level contact your Vac AlertTM representative for further instructions For applications where the pump is located more than 24 below pool or spa water le...

Страница 4: ...at each end DO NOT DROP THE UNIT The Installation Instructions DVD and Quick Installation Guide are located in the box stowed between the box and the lower polystyrene insert If the outer package appe...

Страница 5: ...flow coming from the main drain line If the vacuum level is over 15 see previous suggestions for lowering system running vacuum level NOTE Do not use a flow restricted test valve or a slow acting tes...

Страница 6: ...o mount the SVRS off the installed tee A reducing bushing may also be required to mate the 1 1 2 diameter SVRS to the tee fitting installed Utilize pipe nipples to join fittings in a close coupled fas...

Страница 7: ...em Preparation for options on how to lower system operating vacuum level 2 NOTE Each SVRS comes factory set to remain closed non venting for vacuum levels up to 10 Hg If the pump start up test indicat...

Страница 8: ...ion setting is reached then back the adjustment screw off counter clockwise one revolution The adjustment screw must be positioned properly between the two travel stops to set the Vac AlertTM unit for...

Страница 9: ...dry running of self priming pumps where pump suction lift is less than 42 To make sure the unit is working properly turn off the pump and place the Vac AlertTM SVRS unit in the open venting position W...

Страница 10: ...valve is an optional alternative to a pole mounted test mat Each Vac AlertTM SVRS unit must be tested three 3 times to ensure proper adjustment and operation Where a hydro static valve is present the...

Страница 11: ...ain drain blockage b Using the installed test valve or a pole mounted test mat conduct routine testing of the SVRS device to ensure proper adjustment of the unit The Vac AlertTM Model VA 2000 SVRS uni...

Страница 12: ...s operate in a dry state Any indication that the unit is flooded or water logged as evidenced by water leakage from the SVRS unit requires immediate service attention Immediately shut down the pool or...

Страница 13: ...14...

Страница 14: ...l m m m m l l l l m m m l l...

Страница 15: ...l l l...

Страница 16: ...sceration Under no circumstances should any child ever be left unattended at or by any body of water Never sit lay or swim near or by suction ports suction ttings or main drains THIS PRODUCT IS 3RD PA...

Страница 17: ...ION LOCATION INFORMATION Name of Purchaser ________________________________________________________________ Installation Address _______________________________________________________________ I have...

Отзывы: