4 - CONTROL UNIT

•  Flasher control with/without integrated intermittency function
•  Integrated management for electric locks 12V max. 15VA or 

settable to 24V with dedicated programming. This output can 
also be used to control courtesy lights

•  Inputs for start, stop and pedestrian opening wired 

commands, customisable to open, stop and close

•  Double input for safety devices: “PHO1” during closing and 

“PHO2” during closing and/or opening

•  Possibility of powering 24VDC accessories
•  Input for gate status pilot light signalling the position of the 

leaves

•  Input for external antenna that can be used for increasing the 

range of the transmitters

•  Pause time for automatic re-closing adjustable to between 0 

and 180 sec. with trimmer

•  Obstacle sensitivity adjustment with trimmer
•  Motor force adjustment with trimmer
•  Incorporated radio receiver (433.92MHz), compatible with V2 

rolling transmitters

•  6 signalling LEDs (Paragraph 7).
•  Slow-speed opening and closing (customisable through 

dedicated programming).

5. CONTROL UNIT SETTING

5.1 - TRIMMER ADJUSTMENT

POWER

: adjustment of motor power. Turning the trimmer 

clockwise increases the motor’s power.
To validate the modification it is necessary to programme the gate 
path.

OBS

: Obstacle, sensitivity to obstacles: adjustment of the obstacle 

detection function. Turning the trimmer clockwise increases the 
drive time before obstacle detection (less sensitivity). Therefore, in 
systems with particularly unfavourable mechanical conditions, it is 
advisable to keep the drive time high.

PAUSE

: Pause time before automatic gate closing. Turning 

the trimmer clockwise increases the pause time from 0 to 180 
seconds. Please note: the AUTO dip-switch must be put to ON.

DELAY

: NOT USED

m

 Varying the “POWER” trimmer has no effect until the 

stroke is reprogrammed (par. 8).

5.2 - DIP-SWITCH ADJUSTMENT

DIP

DESCRIPTION OF OPERATION

DIP 1-2
MOTOR

OFF ON

m

 do not change the DIP setting

DIP 3
STEP

ON

Step-by-step command mode: Open / 
Stop / Close / Stop

At every start pulse (wired or via 
transmitter), the control unit performs an 
action. Starts the motor if the automation 
system is stopped, and stops it if it is 
moving.

OFF

Condominium mode

The control unit only accepts commands 
(either wired or via transmitter) for the 
opening phase.
Starts again from zero with the set delay 
when the automation system is open. 
With the automation in the opening 
phase, it continues to open, and with the 
system in the closing phase it reopens 
fully.
The automation can re-close with the 
time set through the “PAUSE” trimmer, 
if the “AUTO” dip-switch is set to ON. 
If not, it is necessary to give a START 
command (either wired or via transmitter) 
with the automation fully open.

DIP 4
AUTO

ON

Automatic closing activated (time set with 
the “Pause” trimmer)

OFF

Automatic closing deactivated

DIP 5
PHO2

ON

Safety devices connected to “PHO2” set 
as photocells (movement stopped during 
opening and closing)

OFF

Safety devices connected to “PHO2” set 
as edges (reverse of opening movement)

DIP 6
HAZ

ON

Intermittent power supply for the flashing 
light

OFF

Fixed power supply for the flashing light

DIP 7
FAST

ON

Immediate re-closing after intervention of 
“PHO1” photocells

OFF

No intervention of the photocells during 
re-closing

DIP 8
FUNC

ON

Reverse opening direction (the system 
must be programmed afterwards)

OFF

Reverse opening direction (the system 
must be programmed afterwards)

Содержание TORQ500A-230V

Страница 1: ...ORREVOLI FINO A 800 KG DI PESO GB 230V ELECTRO MECHANICAL IRREVERSIBLE RACK ACTUATOR FOR SLIDING GATES UP TO 800 KG F OPERATEUR ELECTROMECANIQUE IRREVERSIBLE 230V POUR PORTAILS COULISSANTS JUSQU A 800...

Страница 2: ...300 3 325 88 5 88 5 161 177 70 325 5 150 185...

Страница 3: ...THE AUTOMATION MOVEMENT 8 2 PROGRAMMING OF THE WIDTH OF THE PEDESTRIAN OPENING 8 3 ADVANCED PROGRAMMING OF THE AUTOMATION MOVEMENT 9 LED SIGNALLING 9 1 INPUT STATUS SIGNALLING LEDS 9 2 ERROR SIGNALLI...

Страница 4: ...make any modifications to any part of the automation device or the accessories connected to it unless described in this manual Any other modifications will void the warranty on the product The instal...

Страница 5: ...are authorised for use and closure is not in a public area Examples of this type are gates inside business premises where the sole users are employees or a part of them who have been suitably informed...

Страница 6: ...nigi CN Italy Under its sole responsibility hereby declares that the partly completed machinery model s TORQ500A 230V TORQ800A 230V Description electromechanical actuator for sliding gates is intended...

Страница 7: ...t for the complete setting of the concrete 6 Unscrew the bolts fixing the base to the clamps and put the motor on the plate 7 Insert the 4 grains with their nuts in the proper place Adjust the 4 grain...

Страница 8: ...TOR Check the following points 1 the motor must be on a levelled surface and perfectly parallel to the gate 2 the distance between pinion and rack must be 1 or 2 mm If needed adjust the 4 grains 3 the...

Страница 9: ...r working of the system we suggest to weld the end of stroke brackets on the rack 3 5 MOTOR OVERRIDING SYSTEM mATTENTION before operating the manual release disconnect the power The motor is anyway di...

Страница 10: ...ONAL ACCESSORIES LENGTH OF THE CABLE 10 metres from 10 to 20 metres from 20 to 30 metres Power supply 230V 120V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Photocells TX 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2...

Страница 11: ...immer clockwise increases the pause time from 0 to 180 seconds Please note the AUTO dip switch must be put to ON DELAY NOT USED mVarying the POWER trimmer has no effect until the stroke is reprogramme...

Страница 12: ...230Vac max 15W AUX AUX contact electric lock PH 01 Photocell safety edge Normally closed contact PH 02 Photocell safety edge Normally closed contact GND Common of the PH01 PH02 terminals VA Rated powe...

Страница 13: ...the gate open they have no effect 6 5 GATE OPEN PILOT LIGHT If the photo test which is deactivated by default see Paragraph 11 1 is not used it is possible to connect a gate status pilot light to the...

Страница 14: ...of all the transmitters that you want to program the red radio LED flashes and the green start LED stays on steady 4 Press the SET and RADIO buttons simultaneously or wait 10 seconds to exit the proce...

Страница 15: ...Position the door in the fully closed position 2 Press the SET button for 2 seconds the yellow set LED flashes 3 Press the START button for 1 second the yellow set LED lights up steadily 4 Press the S...

Страница 16: ...lashes when a command is received through King Gates transmitter is off when the control unit is in standby mode 9 2 ERROR SIGNALLING LEDS RED ERROR LED The red error LED signals any errors that hampe...

Страница 17: ...is function the AUX output must be set to courtesy light see Paragraph 10 2 1 Press the RADIO button for 1 second the red radio LED lights up steadily 2 Press the SET button for 1 second the yellow se...

Страница 18: ...seconds to exit the procedure the LEDs return to the normal operating configuration 11 SAFETY DEVICE ADVANCED PROGRAMMING SEQUENCES These programming sequences are not essential to the system s operat...

Страница 19: ...SET and RADIO buttons simultaneously or wait 10 seconds to exit the procedure the LEDs return to the normal operating configuration mIn order to carry out the check on the safety devices the connecte...

Страница 20: ...ramming sequences and the settings adjustable through the dip switches To perform a new programming sequence or make a dip switch trimmer modification effective the protection must be deactivated 1 Pr...

Страница 21: ...throughout the entire manoeuvre If there are multiple photocell pairs these may signal false obstacles Try bridging the PHO1 PHO2 and STOP contacts to verify whether the problem can be resolved Otherw...

Страница 22: ...self as well as to human health As indicated by the symbol opposite throwing away this product as domestic waste is strictly forbidden So dispose of it as differentiated waste in accordance with your...

Страница 23: ...t this period may vary depending on the intensity of use Any inspection maintenance or repairs should only be performed by qualified personnel Even if you think you know how do not modify the system a...

Страница 24: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Отзывы: