background image

ENGLISH

- 41 -

14. F.A.Q

Problem

Symptoms / Causes

Solution

The control unit LEDs
are turned off

Mains power shortage

Check for the presence of input mains voltage - see Paragraph 6

The fuses are damaged. Before 
replacing them, disconnect the 
mains electricity and verify that 
there are no short-circuits in the 
connections

Replace the fuses (see Paragraph 2.3). If the fuses get damaged 
again, before replacing them disconnect all the cables and verify 
the integrity of the PCB

The control unit does not enter
the programming sequence

When the button for accessing a 
programming sequence is pressed, 
all the LEDs flash. The control unit 
protection has been activated

Deactivate the protection - see Paragraph 13.1.

The control unit completes the 
programming sequence, but does 
not respond to commands in the 
standard operating mode

Problems with the safety devices, 
once the programming sequence 
is completed, the green stop and/
or photo LEDs are off

Check that the “PHO1”, “PHO2” and “STOP” contacts are
closed

Photo-test of safety devices failed. 
After a command is pressed for a 
few seconds, the red “error” LED 
turns on”

Deactivate the photo-test - see Paragraph 11.1.

The control unit causes the 
automation to start, but the latter 
does not cover the full path

Obstacle detection problems. If 
during the manoeuvre the control 
unit detects power draw peaks, it 
goes into obstacle present mode.

First of all, verify that the system’s works in the manual mode. 
There must not be any points in which the gate leaf tends to 
stop. Raise the “OBS” trimmer by turning it clockwise (see 
Paragraph 3.2). If insufficient, increase the “POWER” trimmer 
setting and reprogram the stroke. If the problem occurs at the 
final stage of the path, it may be resolved by eliminating or 
minimising the slowdown points (see Paragraph 8.3)

Intervention of the safety devices. 
Check that the green “photo” and 
“stop” LEDs remain lit throughout 
the entire manoeuvre.
If there are multiple photocell 
pairs,these may signal false 
obstacles

Try bridging the “PHO1”, “PHO2” and “STOP” contacts to 
verify whether the problem can be resolved. Otherwise, connect 
the photocells with alternating receivers

The transmitter does not function

When the programming sequence 
mentioned in Paragraph 7.1 is 
completed, the red “radio” LED 
does not flash

Verify the transmitter’s compatibility: the code must be V2.  
If the transmitter’s LED does not light up clearly, replace the 
battery

The transmitter has little range

The transmitter’s range varies 
in relation to the environmental 
conditions

Replace the transmitter’s battery. Should this not be sufficient, 
the control unit is configured for connecting external antennas.

The control unit does not slow
down the gate

If the “Power” trimmer is too 
high, the control unit in the space 
set by default through the gate 
path programming procedure is 
unable to detect the change of 
speed

Reduce the setting of the POWER trimmer and reprogram the 
stroke; if this is not sufficient, program the deceleration points 
(par. 5.3) and set a longer deceleration zone.

The control unit functions 
correctly, but does not accept 
wired start and pedestrian 
commands

When the start or ped contacts 
are closed, the green “start” LED 
emits brief flashes. The command 
lock has been activated

Deactivate the pedestrian and start block. See paragraph 12.2

The control unit does not make 
the dip-switch or trimmer 
modifications effective

Once the dip-switch or trimmer 
positions have been modified, 
the control unit does not make 
the modifications effective. The 
control unit protection has been 
activated

Deactivate the control unit lock. See Paragraph 13.1

Once the “power” trimmer, dip-
switch 1-2 “motor” or dip-switch 
8 “func” positions have been 
modified, no resulting effects 
appear on the system

To make the “power” trimmer or dip-switch 1-2 “motor” 
modifications effective, the basic or advanced path 
programming must be redone. Should this not be possible, the 
control unit lock has been activated. See Paragraph 13.1

Содержание TORQ500A-230V

Страница 1: ...ORREVOLI FINO A 800 KG DI PESO GB 230V ELECTRO MECHANICAL IRREVERSIBLE RACK ACTUATOR FOR SLIDING GATES UP TO 800 KG F OPERATEUR ELECTROMECANIQUE IRREVERSIBLE 230V POUR PORTAILS COULISSANTS JUSQU A 800...

Страница 2: ...300 3 325 88 5 88 5 161 177 70 325 5 150 185...

Страница 3: ...THE AUTOMATION MOVEMENT 8 2 PROGRAMMING OF THE WIDTH OF THE PEDESTRIAN OPENING 8 3 ADVANCED PROGRAMMING OF THE AUTOMATION MOVEMENT 9 LED SIGNALLING 9 1 INPUT STATUS SIGNALLING LEDS 9 2 ERROR SIGNALLI...

Страница 4: ...make any modifications to any part of the automation device or the accessories connected to it unless described in this manual Any other modifications will void the warranty on the product The instal...

Страница 5: ...are authorised for use and closure is not in a public area Examples of this type are gates inside business premises where the sole users are employees or a part of them who have been suitably informed...

Страница 6: ...nigi CN Italy Under its sole responsibility hereby declares that the partly completed machinery model s TORQ500A 230V TORQ800A 230V Description electromechanical actuator for sliding gates is intended...

Страница 7: ...t for the complete setting of the concrete 6 Unscrew the bolts fixing the base to the clamps and put the motor on the plate 7 Insert the 4 grains with their nuts in the proper place Adjust the 4 grain...

Страница 8: ...TOR Check the following points 1 the motor must be on a levelled surface and perfectly parallel to the gate 2 the distance between pinion and rack must be 1 or 2 mm If needed adjust the 4 grains 3 the...

Страница 9: ...r working of the system we suggest to weld the end of stroke brackets on the rack 3 5 MOTOR OVERRIDING SYSTEM mATTENTION before operating the manual release disconnect the power The motor is anyway di...

Страница 10: ...ONAL ACCESSORIES LENGTH OF THE CABLE 10 metres from 10 to 20 metres from 20 to 30 metres Power supply 230V 120V 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 Photocells TX 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2...

Страница 11: ...immer clockwise increases the pause time from 0 to 180 seconds Please note the AUTO dip switch must be put to ON DELAY NOT USED mVarying the POWER trimmer has no effect until the stroke is reprogramme...

Страница 12: ...230Vac max 15W AUX AUX contact electric lock PH 01 Photocell safety edge Normally closed contact PH 02 Photocell safety edge Normally closed contact GND Common of the PH01 PH02 terminals VA Rated powe...

Страница 13: ...the gate open they have no effect 6 5 GATE OPEN PILOT LIGHT If the photo test which is deactivated by default see Paragraph 11 1 is not used it is possible to connect a gate status pilot light to the...

Страница 14: ...of all the transmitters that you want to program the red radio LED flashes and the green start LED stays on steady 4 Press the SET and RADIO buttons simultaneously or wait 10 seconds to exit the proce...

Страница 15: ...Position the door in the fully closed position 2 Press the SET button for 2 seconds the yellow set LED flashes 3 Press the START button for 1 second the yellow set LED lights up steadily 4 Press the S...

Страница 16: ...lashes when a command is received through King Gates transmitter is off when the control unit is in standby mode 9 2 ERROR SIGNALLING LEDS RED ERROR LED The red error LED signals any errors that hampe...

Страница 17: ...is function the AUX output must be set to courtesy light see Paragraph 10 2 1 Press the RADIO button for 1 second the red radio LED lights up steadily 2 Press the SET button for 1 second the yellow se...

Страница 18: ...seconds to exit the procedure the LEDs return to the normal operating configuration 11 SAFETY DEVICE ADVANCED PROGRAMMING SEQUENCES These programming sequences are not essential to the system s operat...

Страница 19: ...SET and RADIO buttons simultaneously or wait 10 seconds to exit the procedure the LEDs return to the normal operating configuration mIn order to carry out the check on the safety devices the connecte...

Страница 20: ...ramming sequences and the settings adjustable through the dip switches To perform a new programming sequence or make a dip switch trimmer modification effective the protection must be deactivated 1 Pr...

Страница 21: ...throughout the entire manoeuvre If there are multiple photocell pairs these may signal false obstacles Try bridging the PHO1 PHO2 and STOP contacts to verify whether the problem can be resolved Otherw...

Страница 22: ...self as well as to human health As indicated by the symbol opposite throwing away this product as domestic waste is strictly forbidden So dispose of it as differentiated waste in accordance with your...

Страница 23: ...t this period may vary depending on the intensity of use Any inspection maintenance or repairs should only be performed by qualified personnel Even if you think you know how do not modify the system a...

Страница 24: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...