ENGLISH
- 38 -
ID
DESCRIPTION
ADJUSTMENT
DEFAULT
18
Unmanaged
Maintaining
0
0
19
Leaf weight selection
0
Self-learning
1
<50kg per leaf
2
50kg-100kg per leaf
3
>100kg per leaf
0
20
Start 1 input polarity
0
NO
1
NC
0
21
Start 2 input polarity
0
NO
1
NC
0
22
Terminal 17 input polarity
0
NO
1
NC
1
23
Not used
0
NO
1
NC
1
24
Not used
0
NO
1
NC
1
25
Terminal 18 input polarity
0
NO
1
NC
1
26
Aux In1 input polarity
0
NO
1
NC
0
27
Aux In2 input polarity
0
NO
1
NC
0
28
Key input polarity
0
NO
1
NC
1
29
Aux Out output polarity
0
NO
1
NC
0
30
Not used
0
NO
1
NC
0
31
Not used
0
NO
1
NC
0
32
First Input Mode
0
Bistable
1
Monostable
0
33
Battery Management
0
Battery Not used
1
Battery Present normal function
2
Battery Present emergency function
3
Battery Present safety function with battery capacity control
0
34
Photocell Management
0
Photocells not used
1
Photocell used one ray
2
Photocells used two rays
0
35
Safe Open
(solw movement )
0
Not active
1
Active
0
36
Unmanaged
37
Elastic mode
0
Not present
1
Present
0
NOTE:
it is always possible to return all the values of the control
unit to the default settings by performing a reset to default as
follows:
1.
press the +/- keys until the
Sd
code appears
2.
press ENT: the value
- -
is shown;
3.
press ENT again and hold down for 5 seconds;
4.
the segments of the display will begin to rotate and afterwards
the message
E6
will appear;
5.
the parameters of the control unit have returned to the factory
settings;
6.
repeat the
LS
and
LP
procedures to acquire the data of the
door required for operation
m
DANGER: in order for the board to function correctly
in accordance with EN16005, parameter 34 must be set
to 0. The selection of values 1 or 2 enables the internal
management circuit of the photocells and disables the test
procedures for the safety devices in opening and closing.
The control unit will operate in a way that does not comply
with EN16005. If parameter 34 is set to a value other than
0, an important safety function may be disabled and the
automatic movement of the doors may cause serious injury
or damage to persons or objects, risking potentially fatal
lesions.
NOTE: if parameter 33 is set to 0, the multi-logic switch
does not signal when the battery is empty. To receive
a notification signal that the battery is empty, select a
value other than 0 on the selector that corresponds to the
behaviour requested in the event of power failure.