ENGLISH
- 50 -
PARAMETER
VALUE
DESCRIPTION
AntE SCor
MEMO
Strt
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 5.4)
StAn StAn
StAn
Standard mode
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
StAn
APCh
Open/Close command
PrES
Dead man operation
oroL
Timer mode
StoP
Stop Input
no
no
no
The input STOP is not available
ProS
The input STOP stops the gate: pressing the command START the gate
continues the motion
invE
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Foto
Photocells Input
This menu allows input to be enabled for the photocells
CFCh CFCh
APCh
Input enabled on opening and closure
CFCh
Photocell active on closure and with gate stopped
Ch
Input enabled for the closing phase only
m
WARNING: If the photocell is damaged the gate is opened
anyway.
Before closing the test of the photocell (if enabled) will detect
the fault and prevent the gate from closing.
no
Input disabled
Ft.tE
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second
no
no
no
Function deactivated
Si
Function activated