ENGLISH
- 46 -
PARAMETER
VALUE
DESCRIPTION
AntE SCor
MEMO
En.SA
ENERGY SAVING function
When the function is active and the LOW ENERGY module is installed,
the control unit deactivates the display, the photocells, and all the
devices powered by a terminal box under determined conditions.
NOTE
: If the LOW ENERGY module is not installed, the control unit
deactivates only the display.
The control unit activates the ENERGY SAVING mode under the
following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
The control unit exits from the ENERGY SAVING mode in these cases:
• If an operational cycle is activated
• If one of the keys on the control unit are pressed
no
no
no
Function deactivated
Si
Function activated
t.AP
Opening time
20.0” 20.0”
0.0”-5’00
Adjustable time from 0 seconds to 5 minutes
t.Ch
Closing time
21.0” 21.0”
0.0”-5’00
Adjustable time from 0 seconds to 5 minutes.
NOTE
: To avoid that the door does not close completely, we
recommend to setup a longer time than
t.AP
opening time.
t.APP
Partial opening time (pedestrian access)
6.0” 6.0”
0.0” - 2’00
When the control unit receives a Start Pedestrian command, it will open
leaf for a shorter time.
Max allowed time to be setup is
t.AP
t.ChP
Partial closing time (pedestrian access)
7.0” 7.0”
0.0” - 2’00
When the control unit receives a Start Pedestrian command, it will use
this time to close the gate. Max allowed time to be setup is
t.Ch
.
NOTE:
To avoid that the door does not close completely, we
recommend to setup a longer time than
t.APP
opening time
t.SEr
Lock time
2.0”
no
0.5”- 1’00
Before the opening phase begins, the control unit will energize the
electric lock in order to release it and enable the gate motion.
t.SEr
time will fix the energizing time.
m
WARNING: in case the gate has no electric lock, set the
value
no
no
Function deactivated
SEr.S
Silent Locking Mode
Si
Si
Si
Function activated (140 Hz)
no
Function deactivated (50 Hz)
t.ASE
Lock advance time
1.0”
0.0”
0.0”- 1’00
While the electric lock is energized, the gate will stay standstill for
t.ASE
time, to make its release easier.
In case
t.ASE
is lower than
t.SEr
, the lock energizing will go on
while the doors will start moving.
m
WARNING:
in case the gate has no electric lock, set the value
0.0”