PARAMETER
VALUE
DESCRIPTION
AntE SCor
MEMO
Ch.tr
Closing after transit
This function allows having a fast closing as soon as transit through
the gate is completed, therefore, a time shorter than
Ch.AU
is
generally used
no
no
no
Function deactivated. The gate closes after the time set for the
function
Ch.AU
0.5” - 20.0’
The gate closes after the setup time
PA.tr
Pause after transit
In order to let the gate open for the shortest possible time, it is
possible to stop the gate once the passage before the photocells is
detected.
If the automatic working is enabled, the time of the pause is
Ch.tr
.
no
no
no
Function deactivated
Si
Function activated
LUCi
Courtesy lights
This menu allows you to set operation of the courtesy lights in
automatic mode during gate operating cycle.
t.LUC t.LUC
no
Function disabled
t.LUC
Operation timed (from 0.0” to 20’0)
1’00
1’00
CiCL
Lights on for the entire duration of the cycle
AUS
Auxiliary Channel
This menu allows you to set relay operation for courtesy lights using a
remote control saved on channel 4 of the receiver
Mon Mon
Mon
Mono-stable operation
biSt
Bi-stable operation
tiM
Timed operation (time set from 0 to 20’0)
toUt
Bi timed operation (time set from 0 to 20’0)
SPiA
Low voltage lights
This menu allows setting the operation of the low voltage lights
output
no
no
no
Function deactivated
W.L.
Indicator light operation: Indicates the status of the gate in real-time.
The type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
FLSh
Flashing light operation (fixed frequency)
LP.PA
Flashing light during pause time
no
no
no
Function deactivated
Si
Flashing light will be on during the pause time too