ENGLISH
- 52 -
14 - QUICK CONFIGURATION
This paragraph concerns a quick procedure to set the control unit
and set it at work immediately.
We recommend following these instructions, in order to
check quickly the correct operation of control unit, motor
and accessories, and then changing the configuration in
case of any non-satisfactory parameter.
1.
Call up the default configuration: see chapter 13
2.
Set items
dir - StoP - Foto - CoS
For the position of the item menus inside the main menu and
for the options related to each item menu, refer to the
chapter 17.
3.
Start the self-learning cycle (chapter 15)
4.
Check that the automation work properly and if necessary
modify the configuration of the desired parameters.
15 - AUTO-LEARNING END-STOP
This menu allows automatically learning the end-stop positions of
the barrier in opening and closing.
m
ATTENTION: before proceeding, make sure to position
the mechanical stops correctly.
m
ATTENTION: before proceeding set the
dir
parameter
m
CAUTION: to perform the self-learning procedure
it is necessary to disable the ADI interface by means of
the menu
i.Adi
(disabled by default). If some safeties are
controlled by means of the ADI module, they will not be
active during the self-learning.
1.
Set the parameter
StoP
,
Foto
,
CoS
, based on the safety
installed on the barrier (chapter 17).
2.
Set up the
St.rt
parameter in
StAn
modality (default)
3.
Maintain hold pressed push-button
OK
until the display reads
-SEt
4.
Release push-button
OK
: the display reads
ESC
(press
push-button
OK
only if desired to exit from this menu)
5.
Press the push-button
i
: the display reads
APPr
6.
Press the push-button
OK
in order to start the auto-learning:
6.1
The boom moves in closing until reaching the arrest
point (end of closing)
6.2
The boom opens. Press
h
when the boom reaches the
desired opening. As alternative let the mechanical arrest
intervene.
6.3
The boom recloses automatically and it memorizes the
length.
During normal operations, the travel height of the boom is always
reported to the point of arrest in closing. Any movements of this
point will cause an equal movement of the end opening point.
7.
If you DO NOT have enabled the obstacle sensor (menu
SEnS
),
the self-learning procedure is completed and the display
shows the control panel
8.
If the obstacle sensor has been enabled, the display shows the
recommended value for the obstacle sensor. If no operations
are performed for 20 seconds, the control unit exits the
programming phase, without saving the value recommended.
9.
The recommended value may be modified by pressing the
h
and
i
keys, and pressing the
OK
key confirms the displayed
value and the display shows
SEnS
10.
Press and hold the
i
key until the display shows
FinE
, then
press the
OK
key, select the option
Si
and then press the
OK
key to exit programming mode, storing the value for the
sensors.
m
ATTENTION: If this procedure is not followed, the
control unit will exit from the Time out programming
(1 min) retaining the last memorized value
Содержание 36A022
Страница 2: ...1153 mm 320 mm 287 mm 218 mm 897 mm 1168 mm 374 mm 239 mm 319 mm 897 mm...
Страница 7: ...ITALIANO 5 NIUBA4 NIUBA6...
Страница 11: ...ITALIANO 9 FIG 3 FIG 4...
Страница 13: ...ITALIANO 11 A D E C F F G E A B D C O N M...
Страница 31: ...ITALIANO 29...
Страница 34: ...ITALIANO 32...
Страница 39: ...ENGLISH 37 NIUBA4 NIUBA6...
Страница 43: ...ENGLISH 41 FIG 3 FIG 4...
Страница 45: ...ENGLISH 43 A D E C F F G E A B D C O N M...
Страница 63: ...ENGLISH 61...
Страница 66: ...ENGLISH 64...
Страница 71: ...FRAN AIS 69 NIUBA4 NIUBA6...
Страница 75: ...FRAN AIS 73 FIG 3 FIG 4...
Страница 77: ...FRAN AIS 75 A D E C F F G E A B D C O N M...
Страница 95: ...FRAN AIS 93...
Страница 98: ...FRAN AIS 96...
Страница 103: ...ESPA OL 101 NIUBA4 NIUBA6...
Страница 107: ...ESPA OL 105 FIG 3 FIG 4...
Страница 109: ...ESPA OL 107 A D E C F F G E A B D C O N M...
Страница 127: ...ESPA OL 125...
Страница 130: ...ESPA OL 128...
Страница 131: ......