12 - EMERGENCY MAN PRESENT OPERATION
This operational mode can be used to move the gate in Man Present mode, even when the
Strt
parameter has not been configured as
PrES
, in particular cases, such as installation/maintenance or in the case of photocell or edge malfunction.
Activation for installation/maintenance
Press and hold
OK
until
SEt
is displayed, then select
Mov
Press and hold
h
to open and
i
to close (as in man present mode).
Exit this mode by pressing
OK
for one second, or after one minute without the gate being moved.
Activation in the case of photocell/edge malfunction
If a safety device stops the gate from starting, it is possible to switch to the “emergency” man present operating mode by keeping the
start commend active for 3 seconds.
Note:
if the
Strt
parameter is set as
StAn
, the Start command (from the terminal block or remote control) moves the gate in the open and
closed directions alternatively (unlike the normal Man Present mode).
Emergency man present mode ends after 10 seconds of the gate not moving.