72
GALILEO 2 TEK (G2TEK) USER MANUAL
The audible signal is repeated for 5
seconds in 1-minute intervals after the first
occurrence, and for as long as the value
of CNS O
2
stays at or above 100% or until
the ppO
2
drops under 0.5bar (see chapter:
Diving with nitrox
for a list of depths at
which the ppO
2
equals 0.5bar for typical
nitrox mixes).
3 .6 .4
Tank reserve pressure
reached
See chapter:
Tank reserve
to learn how
to set the tank reserve pressure limit. When
this set pressure is reached during the dive
an alarm is triggered.
3 .6 .5
Missed decompression stop
WARNING
Violating a mandatory decompression
obligation may result in serious injury or death.
If, when conducting a required
decompression stop, you ascend more
than 0.5m/2ft above the required stop, the
G2TEK will trigger an alarm. The value of
the current depth and the text:
MISSED
DECO STOP!
is shown and a sequence of
beeps can be heard. This will continue for
as long as you stay 0.5m/2ft or more above
the required stop
3 .6 .6
RBT = 0 min
The situation when RBT reaches 0 minutes
can be selected as a warning or alarm. See
chapter:
RBT warning or alarm
to read
more about this setting.