16
GALILEO 2 TEK (G2TEK) USER MANUAL
• Turn on the G2TEK, select menu
8.2.5. Pairing.
• Open the tank valve.
Upon pressurization, the Smart transmitter
will send a pairing sequence to the G2TEK.
When the G2TEK receives this information,
the display changes to show a listing of
tank designations. (
T1
,
T2
, etc.).
Tank
T1
is always the main tank you start
your dive with. Other tanks are used when
diving with more than one gas mixture
(described in chapter:
Diving with
multiple gas mixtures
).
Use the ARROW buttons to select the tank
that you want to assign to the transmitter,
then press SAVE to lock in your selection.
The G2TEK will confirm the pairing with the
message
PAIRING TO T1 SUCCESSFUL
.
If you do not wish to complete the
operation, with a press-and-hold of the right
button the G2TEK will show the message
PAIRING CANCELLED
. The pairing will
also be cancelled if you do not press SAVE
within 3 minutes of tank selection.
F
NOTE: The transmitter must have
been unpressurized for at least 40
seconds prior to performing the
pairing operation; otherwise it will not
transmit the pairing sequence.
Also, a transmitter can only be paired
to one tank designation. If you pair
the same transmitter to a second
tank designation, the first one will
be erased. However, you can pair
more than one G2TEK to the same
transmitter.
After a successful pairing of T1 to the
G2TEK, the display will show the tank
pressure in either BAR or PSI. If tank T1 has
not been paired, the G2TEK will show NO P
instead of a pressure value.
If T1 has been paired but the G2TEK is not
receiving any signal, it will show - - - instead
of a pressure value.
On the surface, the status of tanks T2, T3,
etc. are shown in the gas summary table,
described in chapter:
Gas summary.
F
NOTES:
• The Smart transmitter has a range of
approximately 1.5m/5ft.
• To maximize the life of the battery,
the transmitter operates at a low
update rate when there is no pressure
change for more than 40 seconds.
The transmitter also turns itself off
when the pressure is 14bar/200psi
or less.
• If a transmitter battery is weak, the
G2TEK will alert you with a screen
message displaying the tank assigned
to that transmitter as shown on the
screen below.