49
III Diving with Aladin
®
Pro Nitrox
III
5.1 End of a dive
After reaching the surface, Aladin
®
Pro Nitrox switches into wait-mode
automatically for five minutes. This is the time span necessary to recognize
the end of the dive.
The delay allows for surfacing for a short period for orientation or for a
change of tank.
During the five minutes waiting time the percentage of oxygen display
alternates with maximum depth display.
When the dive is closed after 5 minutes in wait-mode, it is entered into the logbook and Aladin
®
Pro Nitrox
switches into surface-mode.
In surface-mode, Aladin
®
Pro Nitrox shows desaturation time, no fly time and <CNS O
2
LIMIT>).
If the tank is changed in this phase, you must make sure that the mixture is
exactly the same as the one previously used. If you want to dive with another
mixture, you must wait at the surface for 5 minutes to allow the Aladin
®
Pro
Nitrox to close the dive. Then the setting of the mixture must be adjusted to the
new mixture. Disregarding this rule causes the Aladin
®
Pro Nitrox to calculate
with wrong mixture data. This can lead to injury or death.
5 Functions at the Surface
depth
dive time
max. depth
deco info
O
2
% MIX
depth
dive time
max. depth
deco info
O
2
% MIX