39
III Diving with Aladin
®
Pro Nitrox
III
3 Preparation for the Dive
3.2 Setting the gas mixture
Before every dive, you must check if the setting of the gas mixture (percentage of
oxygen) on your Aladin
®
Pro Nitrox corresponds to the mixture in your tank. Reset
the mixture if necessary:
1
Switch on computer manually and check the set percentage of oxygen (O
2
%MIX).
2
Switch to O
2
%MIX input stage by bridging B and –.
3
Confirm by bridging B and E.
4
Bridging B and + will increase the percentage of oxygen (from 21% to 50%),
bridging B and – decreases the percentage of oxygen.
5
Confirm with B and E. Aladin
®
Pro Nitrox switches back into ready-mode.
Before every dive, make sure that the setting of the gas mixture
corresponds to the actual mixture used. A wrong setting causes the
Aladin
®
Pro Nitrox to miscalculation for this particular dive. If the
percentage of oxygen is set too low this can lead to oxygen intoxication
without warning. If the value is set too high decompression damages
due to nitrogen saturation may occur without a warning from the
Aladin
®
Pro Nitrox.
depth
dive time
max. depth
deco info
O
2
% MIX
depth
dive time
max. depth
deco info
O
2
% MIX