SVD48V Series hub motor servo controller user manual
27
550
C
Encoder Bias
Unit: °
Range: -360°~360°
RW
int16
5580
Encoder
temperature
Unit: x0.1
℃
Range: -2000~2000
RO
int16
5584
Calibration
status
0: Calibration successful
1: Calibrating
2: Calibration failed
RO
uint16
5.8.1.2
M2
Encoder parameters
register
address
definition
describe
Attributes Types of Defaults
5501
calibration
0: No calibration
1: Perform calibration
RW
uint1
6
5504
Encoder lines /
bits
Range: 0~32767
RW
uint1
6
5509
Encoder
installation
direction
0: positive
1: Reverse
RW
uint1
6
550
D
Encoder Bias
Unit: °
Range: -360°~360°
RW
uint1
6
5581
Encoder
temperature
Unit: x0.1
℃
Range: -2000~2000
RO
int16
5585
Calibration status
0: Calibration successful
1: Calibrating
2: Calibration failed
RO
uint1
6
5.8.2
Hall Sensor parameters
5.8.2.1
M1 Hall
Sensor parameters
register
address
definition
describe
Attributes Types of Defaults
5600
calibration
0: No calibration
1: Perform calibration
RW
uint1
6
5620
Hall installation
0: 120°
1: 60°
RW
uint1
6
5624
Calibration current Range: 0~50A
RW
uint1
6