42
detected
abnormal
often
The hardware
circuit is abnormal
After-sales
5
Drive 12V
abnormal
Abnormal
hardware circuit
Please contact after sales
6
Drive 5V
abnormal
External output
5V short-circuit
road or
overcurrent
The total current of the external 5V
load cannot exceed 1A, if
If it exceeds 1A, please use another
power supply
7
Motor circuit
open
The motor wire is
not connected
Check the motor cable connection
run error
code
8
Drive
temperature is
too high
long-term high-
load operation
Add a 5V fan while optimizing drive
enclosure cooling
environment
9
Motor
temperature is
too high
long-term high-
load operation
Reduce the motor load, or use a
higher power motor
10
Motor
overcurrent
protection
Motor wire short
circuit
Replace the motor
11
Motor overload
protection
Motor is subject to
specified overload
Guard Time Stall
1.
Appropriate software to increase
overload protection time;
2.
Please use a higher power motor
12
Overvoltage
protection
Unstable supply
voltage
1.
It is recommended to use a higher
current power supply, or use a
battery pack for power supply;
2.
Properly increase the motor
acceleration ramp time
13
Undervoltage
protection
Unstable supply
voltage
1.
It is recommended to use a higher
current power supply, or use a
battery pack for power supply;
2.
Properly increase the motor
deceleration ramp time
14
Encoder input
abnormal
The encoder plug
is disconnected or
The encoder is
damaged
1.
Check whether the encoder line is
connected normally;
2.
Replace the encoder or motor
15
wrong hardware
version
wrong firmware
upgrade