![UUMOTOR SVD48V Series Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/uumotor/svd48v-series/svd48v-series_user-manual_1065775026.webp)
SVD48V Series hub motor servo controller user manual
25
530
C
given location
Optical encoder: line number*4LSB
Magnetic encoder: coding
range*1LSB;
Range:
-2147483648
~
2147483647
RW
Int32
0
5.6.2
M2 Motor Control Parameters
register
address
definition
describe
Attributes Types of Defaults
5301
control
commands
0: stop
1: start
2: Clear the alarm
RW
uint1
6
0
5305
given speed
Unit: rpm;
Range: -32768~32767
RW
int16
0
5309
given current
Unit: x0.1A
Range: -32768~32767
RW
int16
0
530E
given location
Optical encoder: line number*4LSB
Magnetic encoder: coding
range*1LSB;
Range:
-2147483648
~
2147483647
RW
Int32
0
5.7 Motor status parameters
5.7.1
M1 Motor status parameters
register
address
definition
describe
Attributes Types of Defaults
5400
Motor
running
status
0: stop
1: Running
RO
int16
0
5404
Motor
temperature
Unit: 0.1
℃
Range: -2000~2000
RO
int16
0
5408
bus voltage
Unit: 0.1V
Range: 0~2000
RO
int16
0
540
C
MOS tube
temperature
Unit: 0.1
℃
;
Range: -2000~2000
RO
uint16
0
5410
Motor speed
Unit: rpm
Range: -32768~32767
RO
int16
0
5414
Motor current
Unit: 0.1A
Range: -5000~5000
RO
int16
0
5418
Motor
absolute
position
Optical encoder: line number*4LSB
Magnetic encoder: coding
range*1LSB
Range:
-2147483648
~
2147483647
RO
int32
0