![UUMOTOR SVD48V Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/uumotor/svd48v-series/svd48v-series_user-manual_1065775017.webp)
SVD48V Series hub motor servo controller user manual
16
3009
Maximum
bus
voltage
X0.1V ; the overvoltage protection voltage of
the driver. If the bus voltage is greater than
this value before starting the motor , the
drive will report an error. During operation,
the regenerative braking causes the
voltage to rise. When it rises to the
protection voltage, the driver will limit the
regenerative current, so that the bus
voltage is generally not higher than the
voltage of 8V; when the voltage is higher
than the voltage of 15V, the driver will turn
off output, and an error is reported. It is
recommended that the 6S lithium battery
power supply is set to 28V; the 14S lithium
battery power supply is set to 54V
RW
uint16
300A
Overload
timeout
between
ms; timeout after overload, trigger protection
after timeout
RW
uint16
300B
Encoder
power-
on
calibrati
on
When the drive is powered on, the motor will
be calibrated once
RW
5.2 Board control parameters
5.2.1
Basic parameter function
register
address
definition
describe
Attributes Types of Defaults
3100
save parameters 0: Do not save parameters to FLASH
1: Save parameters to FLASH
WO
uint1
6
3180
Drive in-position
flag
fixed at 1
The host computer is used as a
heartbeat package
RO
uint1
6