SVD48V Series hub motor servo controller user manual
24
5238
Speed feed
forward gain
Range: 0~1.0
RW
float
5240
speed loop
dead zone
Range: 0~100
RW
uint1
6
5.5.2
M2 motor PID parameters
register
address
definition
describe
Attribut
es
Types of Defaults
5202
Speed Kp
Range: 0~127.999
RW
float
520A
Speed Ki
Range: 0~127.999
RW
float
5212
Speed Kd
Range: 0~127.999
RW
float
521A
Location Kp
Range: 0~127.999
RW
float
5222
LocationKi
Range: 0~127.999
RW
float
522A
Location Kd
Range: 0~127.999
RW
float
5232
Current loop
gain
Range: 0~1.0
RW
float
523A
Speed feed
forward gain
Range: 0~1.0
RW
float
5241
speed loop
dead zone
Range: 0~100
RW
uint1
6
5.6 Motor control parameters
5.6.1
M1 Motor Control Parameters
register
address
definition
describe
Attributes Types of Defaults
5300
control
commands
0: stop
1: start
2: Clear the alarm
RW
uint1
6
0
5304
given speed
Unit: rpm;
Range: -32768~32767
RW
int16
0
5308
given current
Unit: x0.1A
Range: -32768~32767
RW
int16
0