23
4.
Then turn center screw clockwise until sensor X2 & X3 start to increase in
force (grams).
Note if the sensors start to increase within the first half turn,
repeat step 2, as the pressure plate was too low.
5.
Stop turning when the both sensors have increased to approximately 50 grams.
Note there will be a slight difference between sensors, but this is acceptable if
less than 100 grams
.
6.
Retighten clamping nut. Lid adjust is complete.