background image

   

DAX-­‐16   Installation   &   Operation   Manual   

   

Rev   1.4   

   

3   

 

Safety  Noti

ce

  

  

Review   the   following   safety   precautions   to   avoid   injury   and   prevent   damage   to   this   product.      To   avoid   
potential   risk,   use   this   product   only   as   specified   and   only   for   the   purpose   described   in   the   instruction   
manual.   
   

To   Avoid   Fire   and   Personal   Injury:   
   

 

Use   correct   power   cable

.      Use   only   the   power   cable   provided.      Ensure   that   the   AC   power   outlet   is   

located   near   the   product   and   is   easily   accessible.   

 

Use   a   correctly   grounded   power   source.      

The   power   supply   earth   ground   is   established   through   the   

ground    conductor    in    the    power    cable.        To    avoid    the    potential    of    electric    shock,    the    ground   
conductor   must   be   correct.

   

 

Observe   source   ratings.      

To   avoid   risk   of   fire   or   electric   shock,   the   power   source   must   be   100   –   240   

VAC,   50   –   60   Hz.

   

 

Do   not   operate   with   suspected   failures.      

If   you   suspect   there   is   damage   or   malfunction   with   this   

product,   call   the   factory.

   

 

Do   not   attempt   repair.         

Only   a   trained   factory   service   person   is   authorized   to   repair   this   product.

   

 

Do    not    operate    this    product    near    heat    sources.       

This    product    should    not    be    located    near    heat   

sources

   

such   as   radiators,   heat   registers,   or   stoves.

   

 

Provide    proper    ventilation.       

The    operating    temperature    range    is    between    0º    C    and    40º    C.        The   

humidity   range   is   between   20%   and   80%,   non-­‐condensing.      The   cooling   method   is   convection.

   

 

Keep   product   surfaces   clean   and   dry.      

Disconnect   the   power   cable   from   the   power   source   before   

cleaning.      Do   not   use   liquid   cleaners   or   aerosol   cleaners.      Use   a   damp   cloth   for   cleaning.

   

 

Do   not   push   objects   into   openings   of   this   product.

      Never   insert   objects   into   the   product   through   

openings.

   

 

Do   not   operate   in   wet   or   damp   conditions.   

 

Do   not   operate   in   an   explosive   atmosphere.   

 

Inspect    the    power    cable    and    all    cables    prior    to    use.       

Confirm    that    the    power    cable    and    other   

interconnecting   cables   are   free   from   damage.

   

   

Le

gal  Notices

  

   

The   DAX-­‐16   includes   technology   used   under   license   from   Harman   International   Industries.   

Regulatory  Compliance

  

   
EN   60950-­‐1   

The   EN   60950-­‐1   standard   specifies   the   safety   design   requirements   that   reduce   or   eliminate   the   risk   of   
personal   injury   to   both   the   product   user   and   service   personnel.      This   product   is   designed   and   tested   to   
meet   the   standards   of   the   International   Electrotechnical   Commission   (IEC)   European   Norm   EN   60950-­‐1,   
IEC    60950-­‐1    (the    standard    for    information    technology    equipment    including    electrical    business   
equipment).      

   
Le   Résumé   de   la   Sécurité   general   Européen   

Содержание DAX-16

Страница 1: ...181 Bonetti Dr San Luis Obispo CA 93401 USA 1 805 549 0161 Office 1 805 549 0163 Fax DAX 16 Installation and Operation Manual...

Страница 2: ...ent Class 6 Disposal and Recycling 6 Introduction 7 Features 7 Specifications 8 Model Numbers 9 Browser Support 10 Front Panel 11 Rear Panel 11 DAX 16 Output Assignments 12 DAX 16 Installation and Con...

Страница 3: ...as radiators heat registers or stoves Provide proper ventilation The operating temperature range is between 0 C and 40 C The humidity range is between 20 and 80 non condensing The cooling method is c...

Страница 4: ...iateurs registres de la chaleur po les ou amplificateurs Fournissez Ventilation Ad quate La temp rature dufonctionnement devrait tre entre 0 C et 40 C L humidit devrait tre 20 et 80 La m thoderefroidi...

Страница 5: ...t sollte sein 20 und 80 Die erfrischend Methode ist durch Konvektion und einen innereren F cher Bleiben Sie Produkt Oberfl chen reinigen und Trocken Trennen Sie das Macht Kabel von der Macht Quelle vo...

Страница 6: ...hnology Video and similar Electronic Apparatus IEC 60950 Safety Requirements CE UL cUL Safety and Overall Compliance VDE Certified Power Cords Pollution Not intended for environments where conductive...

Страница 7: ...audio from the multiple units Outputs can be named by the user to indicate a speaker position and band for applications where the crossover is in the sound processor Buttons and level indicators take...

Страница 8: ...h two channels per connector Amplifier Returns o 16 amplifier returns on 8 DE 15 amplifier connectors o Levels can be monitored o Returns can be listened to on audio stream Ethernet 10 100Mbps AES EBU...

Страница 9: ...available in two different versions as shown in the table below Model Inputs DAX 16S 16 channels of AES EBU on two RJ45 connectors Analog bypass on pluggable terminal strip DAX 16N 256 channels 48kHz...

Страница 10: ...touch after slide Fedora 19 Arora 0 11 0 PCM supported New level sent during slide Fedora 19 Firefox 30 0 ADPCM and PCM supported New level sent on mouse up When using arrow keys new level sent on tab...

Страница 11: ...te failure If the button is pressed momentarily after the system has powered up after the front panel LEDs have stopped flashing the configuration on the SD card is copied into the system and to flash...

Страница 12: ...will behave when the DAX 16 is in bypass loss of digital input The DAX 16 bypass circuitry contains a passive crossover that supports full range biamp and triamp operation The system is intended to dr...

Страница 13: ...has analog outputs Use the left channel analog output as a bypass output 5 Open a web browser on the laptop computer Enter 169 254 1 12 in the address field The home page see figure 1 should appear If...

Страница 14: ...In BLU link systems connector A is the IN port and connector B is the OUT port The IN port should be connected to the OUT port of the previous device in the loop The OUT port should be connected to th...

Страница 15: ...DAX 16 Installation Operation Manual Rev 1 4 15 Figure 6 DAX 16 audio configuration page...

Страница 16: ...o reduce pumping and the release time can be decreased to increase the average volume 17 If desired sent Bypass on digital input loss to Enabled An analog bypass signal fed to the DAX 16 on the rear p...

Страница 17: ...card If this page says Could not initialize SD card or some other error message ensure an SD card is in place and that its write protect is not enabled SD cards are write protected or locked when the...

Страница 18: ...utput level on each channel The buttons below the bars are labeled with channel and band information provided during system configuration Pressing the buttons enable and disable audio from that channe...

Страница 19: ...T will show the cause of the error Clicking on the BLU link status box will bring up a page of BLU link registers that can help troubleshoot any issues Firmware Updates USL may issue firmware updates...

Страница 20: ...M 8E 10 Signal Ground reference for Vmon and Imon 11 Channel B input 12 No Connect 13 Channel B Vmon output voltage monitor 14 Channel B Imon output current monitor not used by DAX 16 15 No Connect RJ...

Страница 21: ...find most USL products on your network Double click on the product to open a web browser pointed to that product Appendix C System Restore The DAX 16 has a restore button on the front panel It can be...

Страница 22: ...by it will be free from defects in material and workmanship under normal usage over a period of one 1 year after its purchase new from and authorized dealer Our obligation under this warranty is limit...

Страница 23: ...nual Revisions Rev Description Date 1 0 Original manual 140707 1 1 Formatting Standardized 140709 1 2 Fixed typos changed LED threshold added specifications 140714 1 3 Revise info on bypass 140715 1 4...

Страница 24: ...DAX 16 Installation Operation Manual Rev 1 4 24...