LPV SEED TREATER
LOSS
-
IN
-
WEIGHT WITH ATOMIZER CHAMBERS
The atomizer chamber operates the same way with the Loss In Weight and Seed Me-
tering wheel version. The difference is the way that the seed flow is regulated. The
adjustable gate on the Loss In Weight version is automatically controlled by an actua-
tor that is constantly adjusting the seed flow gate. The actuator is controlled by the U
-
Treat automation software to determine the flow rate of the seed flowing down on top
of the distribution cone which disperses the seed down around the atomizer head. The
atomizer can be easily accessed for cleaning and maintenance by pulling down on the
quick release handle and sliding the atomizer away from the treater body (see page
37).
The gate may also be located on: 1) Batch Hopper either above the treater or on the
floor, 2) Tri
-
Flo mounted on the floor.