Table 3-108: Valid <max_rate> Range
Table 3-109: Valid <max_rate> for each <carrier>
Table 3-110: +MS Extended Syntax Commands
Once a modulation is selected by the
+MS
command, the autorate in both
directions and the automode will be activated unless <max_rate> is specified by
the same command.
The settings of this command overwrite the settings of S28, S37, S38, S109.
Likewise, changes to these registers overwrite the settings of the
+MS
command.
+MSC=<src_v34>—Seamless Rate Change Enable
Use this command to enable or disable V.34 seamless rate changes. Result
codes:
OK
if <src_v34> = 0, 1.
ERROR
if <src_v34> does not equal 0, 1.
Value Meaning
0
Determined by modulation selected in <carrier> (default).
300—57333
Value limited by modulation selected in <carrier>.
Value Meaning
V92
28000 bits/s—57333 bits/s in steps of 1333 bits/s.
V90
28000 bits/s—57333 bits/s in steps of 1333 bits/s.
V34
2400 bits/s—33600 bits/s in steps of 2400 bits/s.
V32bis
4800 bits/s—19200 bits/s in steps of 2400 bits/s.
V32
4800 bits/s—14400 bits/s in steps of 2400 bits/s.
V22bis 2400
bits/s.
V22 2200
bits/s.
V23C, Bell212A
1200 bits/s.
V.21, Bell103
300 bits/s.
Command Description
+MS=<carrier>,<automode>,
<min_rate>,<max_rate>
Select or deselect transmission of the rate report result code.
+MS?
Display the current status of the rate report result code.
+MS=?
Display the supported parameter values for DTE-DCE local
rate reporting.
Содержание 56 1
Страница 1: ...56K Softmodem Command Reference R46 2021 00 rev 1 4 10...
Страница 2: ......
Страница 6: ...56K Softmodem Command Reference vi...
Страница 8: ...56K Softmodem Command Reference 2...
Страница 78: ...56K Softmodem Command Reference 70 Microsoft is a registered trademark of Microsoft Corporation...
Страница 88: ...56K Softmodem Command Reference 80...