dialing strings. The dial string may contain up to 34 characters. The
ATDS=<storage location>
command (see “D<dial string>—Dial” on page 8) dials
using the stored string.
Result codes:
OK
if <storage location> = 0—3.
ERROR
if <storage location> does not equal 0—3.
\A<value>—Select Maximum
MNP
Block Size
The modem will operate an
MNP
error corrected link using a maximum block size
controlled by the
\A
parameter. Result codes:
OK
if <value> = 0—3.
ERROR
if <value> does not equal 0—3.
Table 3-33: \A<value> Commands
\B<break time>—Send Break
Use this command in non-error-controlled mode. It instructs the modem to
transmit a break signal to the remote modem. The minimum break length is 100
ms and the maximum break length is 900 ms. The <break time> parameter has
values between one and nine with each increment representing 100 ms.
The command works in conjunction with the
\K
command (see “\K<value>—Set
Break Control” on page 27).
Result codes:
OK
if <break time> = 1—9 and connected in data modem mode.
ERROR
if <break time> does not equal 1—9.
NO CARRIER
if not connected or if connected in FAX modem mode. This result is
contingent upon have a valid <break time>.
\G<value>—Modem Port Flow Control
Instructs the DCE to process XON/XOFF flow control or pass XON/OFF flow
Command Function
\A0 64
characters.
\A1 128
characters.
\A2 192
characters.
\A3
256 characters (default).
Содержание 56 1
Страница 1: ...56K Softmodem Command Reference R46 2021 00 rev 1 4 10...
Страница 2: ......
Страница 6: ...56K Softmodem Command Reference vi...
Страница 8: ...56K Softmodem Command Reference 2...
Страница 78: ...56K Softmodem Command Reference 70 Microsoft is a registered trademark of Microsoft Corporation...
Страница 88: ...56K Softmodem Command Reference 80...