6
−−−−
sec.3e
2 VOICE - Technical Manual
PUSH BUTTON PANEL
STRUCTURE
2
4
5
6
3
1
12
13
14
11
8
9
10
7
Front view
Rear view
Camera
Signalling yellow led
Microphone
Pre-wired buttons
Name holders
Loudspeaker
Rotary-switch for pedestrian door lock release activation time
Auxiliary settings dip-switch
Identi
fi
cation code dip-switch
Busy time rotary-switch
Connector for expansion module
Loudspeaker volume adjustment
Microphone volume adjustment
Terminal blocks
DESCRIPTION OF TERMINALS
]
LINE Bus line in
SE+
Positive for pedestrian electric lock activation
SE-
Negative for pedestrian electric lock activation
A
[
V3 Surveillance camera 1 signal
V5 Reference for surveillance camera 1 signal
B
[
V3 Surveillance camera 2 signal / video switch
V5 Reference for surveillance camera 2 / video switch
]
ILA
Hard of hearing device output
]
SE2
Driveway electric lock activation
T+
Command for video switch
T-
Reference for video switch
CT
Reference for PA and SP
PA
Entrance hall button
SP
Open door detector (*)
]
ILL
Power supply for name holders lighting
-
}
Do not use
+
EXP Connector for expansion module Ref. 1083/17
I2C Connector for module with voice messages and led
Ref.
1158/47
(*)
the terminal pin SP is connected by default to the terminal pin
CT; to connect the normally close door sensor (with closed door),
remove the jumper.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
PUSH BUTTON PANEL SINTHESI STEEL
VIDEO DOOR UNIT WITH 2 BUTTONS Ref.1083/63 (2 MODULES – 60 Hz)
PUSH BUTTON PANEL SINTHESI STEEL
TECHNICAL CHARACTERISTICS
Power supply voltage (LINE): ..........................................
36 - 48 V
Standby current consumption: .........................................
Max 45 mA
Max. current consumption: ............................................
Max 250 mA
(video call and name holders on)
Name holders lighting ILL output: ..........
11 - 13,8 V
Max 200 mA
Lock output SE+ and SE-: .........................
22 - 24 V
Max 200 mA
SE2 switched load: ..........................................
Max 300 mA 125 V
Operating temperature range: ...........................................
-10 ÷ 50°C
0,9 m
1,0 m
87°
Vertical field of view
1,0 m
1,4 m
1,4 m
108°
Horizontal field of view
0,9 m
DEFAULT CONFIGURATION
Function
Default
Corresponding
Dip-switch
PE type:
Main (OFF) Dip-switch 1 of AUX
Secondary number:
0 (OFF)
Dip-switch 2 of AUX
Door opener:
Free
(OFF)
Dip-switch 3 of AUX
Interruption:
Not
assured
(ON)
Dip-switch 4 of AUX
Camera lights on:
Enabled
(ON)
Dip-switch 5 of AUX
Guaranteed conversation time:
30 s
(pos 3)
Rotary switch -
CONV TIME
Door lock release time:
1 s
(pos 0)
Rotary switch -
DOOR TIME
Door unit number:
0 (OFF)
Dip-switch 1÷5 of ID
=
=
ON
ON