sec.3e
−−−−
25
2 VOICE - Technical Manual
PUSH BUTTON PANEL
5. Restore the rotary switches to the initial position to quit
programming mode.
The function can also be deactivated by performing the general
PROGRAMMING DATA DELETION procedure.
ASSOCIATION OF DOOR UNITS BUTTONS TO
USERS
MAIN DOOR UNITS
By default, the buttons are associated with the users from 0 to 63 of
the riser to which it belongs if the door unit is con
fi
gured as secondary
unit.
If the door unit is con
fi
gured as main, buttons are automatically
associated to column 0; this makes installation of main call stations
easier in one-column systems.
User = 2
User = 3
User = 0
1083/64
User = 1
User = 4
User = 5
User = 6
User = 7
User = 8
User = 9
User = 62
User = 63
If the door unit is con
fi
gured as main and in the system there are
several columns, an association between buttons and users of the
different columns is needed. Follow the instructions below:
1. Gain access to advanced con
fi
guration by rotating both the dip-
switches in position 9 (the yellow led turns on).
2. Place the ID dip-switch with the code of the
fi
rst column of the
system (typically column 0).
3. Press the button associated to the user 0 of the selected column.
All next buttons are automatically associated to the users of that
column, in sequence.
4. Repeat steps for all the columns.
5. Put again the ID dip-switches in their original position.
6. Quit the advanced con
fi
guration, by putting again the two rotary
switches in the positions used to set door lock release time and
guaranteed communication time. The yellow led switches off.
Example:
System with 3 columns, the
fi
rst one with 3 users, the second with 6
users, the third with 9 users.
Column 0
Column 1
Column 2
2VOICE
power supply
2VOICE
power supply
Column
interface
ID = 0
Main
call station
ID = 0
Column
interface
ID = 1
Column
interface
ID = 2
2VOICE
power supply
2VOICE
power supply
Gain access to advanced con
fi
guration.
Set the ID dip-switch to 0.
Press the top button of the door unit “A”.
Set the ID dip-switch to 1.
Press button 2 of the
fi
rst button module “B” which is then
associated to the user 0 of column 1.
Set the ID dip-switch to 2.
Press button 4 of the “C” button module, which is then associated
to the user 0 of column 2.
Put again the ID dip-switches in their original position.
Quit the advanced con
fi
guration.
The
fi
nal con
fi
guration is the following:
3 USERS
B
C
D
E
A
6 USERS
9 USERS
Column 1 start
Column 0 start
Column 2 start
Col = 0 USER = 0
Col = 0 USER = 1
Col = 0 USER = 2
Col = 0 USER = 0
Col = 1 USER = 1
Col = 1 USER = 2
Col = 1 USER = 3
Col = 1 USER = 4
Col = 1 USER = 5
Col = 1 USER = 0
Col = 2 USER = 1
Col = 2 USER = 2
Col = 2 USER = 3
Col = 2 USER = 4
Col = 2 USER = 5
Col = 2 USER = 6
Col = 2 USER = 7
Col = 2 USER = 8
•
•
•
•
•
•
•
•
•
PUSH BUTTON PANEL SINTHESI STEEL
ASSOCIATION OF DOOR UNITS BUTTONS TO USERS
PUSH BUTTON PANEL SINTHESI STEEL