background image

16

DS1332-107B

17

DS1332-107B

GENERIC INFORMATION

CONFIGURATION 

The system capacity is de

fi

 ned by:  

1 trunk line. 

1 extension line. 

2 door phone lines 4+n.

TYPES OF DEVICES

The telephone interface can operate either with Urmet Ref.1332 dedicated combiphones and Director2 

telephones (combiphone operating mode), or with keypad BCA telephones (with DTMF) or equivalent 

terminals (fax, answering machine, etc.) with BCA operating mode.    

Urmet combiphones and Director2 telephones make door phone functions easier, because they are provided 

with dedicated buttons; for example, it is possible to open the door simply by pressing a button. Up to 5 

telephones max. can be connected in series in a system with in/out sockets (refer to enclosed diagrams).

TYPES OF SYSTEM

 

The Ref. 1332/40 telephone interface can be used in the following Urmet door phone systems:

Door phone systems with electronic call system (switch set on 

1A

).

Door phone systems with traditional call system (door phones Mod. 1130, the interface switch set on 

1

). 

It cannot be connected in the following systems: 

Door phone systems with conversation privacy function. 

Door phone systems with concierge switchboard Mod. 604. 

The two calling modes are selected by means of a switch present on the interface. By default, the telephone 

interface is set for the electronic call system (position 

1A

). Actually, with the interface it is possible to replace 

the door phone with a telephone, in order to use the same devices to perform both the telephone and door 

phone functions. 

POWER SUPPLY

The telephone interface must be powered by a voltage of 12Vac, for example by a Ref. 9000/230 transformer 

connected to the mains by a 2-pole circuit breaker. The mains presence is signalled by the POWER led 

present on the interface, that turns on. In case of mains fail, the interface directly transfers the telephone 

line to the devices, allowing, in any case, the telephone service, while the door phone service is not active 

until the mains returns. 

 

OPERATING MODES

 

The telephone interface may work in two operating modes, that can be selected by a programming 

procedure performed with the telephone (paragraph 3.9):

Mode A 

By picking the handset up, the user is immediately connected to the telephone line (no number needs to be 

dialled to access the telephone line).

Mode B 

When the handset is picked up, a dial tone is heard: the telephone is not connected to the telephone line or 

to the door phone line. So the user can access the telephone or door phone line by entering codes.

By default, the interface is preset in mode 

A

1 TELEPHONE SERVICES ON TRUNK LINES AND USE

1.1 CALL ON TRUNK LINE

The interface uses only the multi-frequency dialling mode (MF).

To perform a call on trunk line with the interface in mode A (the line is already present on the 

telephone):

1.  Pick the handset up and wait for the dialling tone.

2.  Select the desired number. 

To perform a call on trunk line with the interface in mode B: 

1.  Pick the handset up and wait for the dialling tone.

2.  Select the number to seize the telephone line, by entering the programmed code (Italy 0 or foreign 

countries 9).

MODE

ITALY

FOREIGN COUNTRIES

CODE TO BE ENTERED

0

9

3.  Wait for the dialling tone.

4.  When the dialling tone is heard, dial the number to be called; start dialling 

within 10 seconds

.

1.2 ANSWER TO AN EXTERNAL CALL

A call coming from a trunk line is signalled by the external call ringing cadence.

To answer:

1.   Pick the handset up and start with conversation.

1.3 DISABLING

The telephone is disabled if, 20 seconds after picking up the handset of one of the devices, no operation 

is performed or a wrong or not allowed operation is performed, regardless of the selected operating mode 

(A or B).  

If the mode B has been selected, after 10 seconds the interface sends an alert tone. To activate again the 

telephone, hang the handset up.

1.4 EMIT A FLASH (R) ON THE TRUNK LINE

Some telephone services require to emit a FLASH on the trunk line. To do this, press twice 

R

 or 

twice the 

sequence # #

. The 

fl

 ash will be emitted on the line and it will be possible to go back in conversation with 

the same. 

Содержание 1332/40

Страница 1: ...DS 1332 107B LBT 8367 Mod 1332 INTERFACCIA TELEFONICA TELEPHONE INTERFACE Sch Ref 1332 40 MANUALE D USO PROGRAMMAZIONE E INSTALLAZIONE USER PROGRAMMING AND INSTALLATION MANUAL...

Страница 2: ...sterno dell inoltro della chiamata citofonica mediante un tono Messa in attesa della conversazione telefonica Apertura della porta 1 Apertura della porta 2 Chiamata a centralino di portineria sistemi...

Страница 3: ...la linea esterna Per fare ci sufficiente premere due volte R oppure due volte la sequenza Si emetter il flash in linea e si torner in conversazione con la stessa MODALIT MODO BCA MODO CITOTELEFONO COD...

Страница 4: ...o di dissuasione o silenzio per liberare la linea citofonica Se non si desidera che la segreteria telefonica entri in funzione con le chiamate citofoniche collegarla direttamente sulla linea telefonic...

Страница 5: ...possibile programmare i tempi di attivazione del rel attuatore ATT1 Dopo essere entrati in programmazione con la procedura descritta in precedenza bisogner inserire il numero del parametro 03 e il val...

Страница 6: ...erno sentir un tono che segnala l inoltro della chiamata verso l abitazione Dopo essere entrati in programmazione con la procedura descritta in precedenza bisogner inserire il numero del parametro 10...

Страница 7: ...unicazione di terminali telefonici non omologati ATTENZIONE SI RACCOMANDA L INSTALLAZIONE DELL INTERFACCIA TELEFONICA ALL INTERNO DI IMPIANTI DOTATI DI APPOSITE PROTEZIONI DI LINEA TELEFONICA ED ELETT...

Страница 8: ...activated However it is possible to make and receive telephone calls because in this condition the telephone equipment is directly connected to the trunk line In this case it is not necessary to dial...

Страница 9: ...not active until the mains returns OPERATING MODES The telephone interface may work in two operating modes that can be selected by a programming procedure performed with the telephone paragraph 3 9 Mo...

Страница 10: ...ANSWER TO DOOR PHONE CALLS COMING FROM DOOR UNIT 1 OR DOOR UNIT 2 The door phone call is signalled on the telephones by a different ringing cadence according if it comes from the door unit 1 or 2 The...

Страница 11: ...lue also in case of mains fail In the following cases will be emitted an error tone for 3 seconds Error during parameter input Error during value input Wrong dialling during programming procedure Fail...

Страница 12: ...r 08 and the desired value according to the table below By default is set the value 1 i e Italy Parameter 08 Value 1 2 3 4 5 6 7 8 9 Activation time Italy France Belgium Israel Holland Ireland Czech R...

Страница 13: ...the telephone line Relay outputs characteristics Switching voltage 63Vac max Switching current 1Amax Programmable contact closing time 1s 2s 4s 10s Operational temperature 5 40 C Relative humidity 10...

Страница 14: ...tables The realization of internal telephone systems should be performed by a skilled technical staff Installation and connection to telecommunication network of telephone not approved are not allowe...

Страница 15: ...stances are between door unit and most distant interface Lay the wires at a suitable distance from power lines as far away as possible If not present in diagram plan 2 conductors for entrance panel na...

Страница 16: ...ection of telephone interface Connection is an of a extension 4 N door phone riser SC104 0192A Collegamento dell interfaccia telefonica a 2 portieri elettrici PE Due chiamate provenienti dai PE Soluzi...

Страница 17: ...actured by Urmet Electronics Limited an Urmet group company Made in P R C URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Collegamento dell int...

Отзывы: