24
DS1332-107B
25
DS1332-107B
TABLE OF TONE AND SIGNALLING
Tone to apartment
stations
Timing
Meaning
Dial tone
Continuous
The interface is waiting for dialling
Deactivation or error
200ms/ 200ms
Wrong operation
Con
fi
rmation
100ms/ 100ms/ 100ms/
100ms/ 100ms/ 1500ms
Service/programming con
fi
rmation
accepted
Door phone call notice
0,1s/ 4,9s
Presence of door phone call
Telephone call notice
0,1s/ 4,9s
Presence of telephone call
On hold
0,1s/ 4,9s
The caller has been put in hold mode
TABLE OF CALL TIMES AND SIGNALLING
Call
Timing for Italy
External
1000ms/ 4000ms
Back from hold
1000ms/ 4000ms
Doorbell 1 door phone
0,25s/ 0,5s/ 0,25s/ 3,85s
Doorbell 2 door phone
0,25s/ 0,5s/ 0,25s/ 0,5s/ 0,25s/ 0,5s/ 0,25s/ 2,35s
4.0 TECHNICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Power supply:
12Vac ± 10% 50/60Hz
Current consumption:
3VA (standby) 10VA (max)
No load voltage:
on telephone terminal pins: 24Vdc< Vbat <52Vdc
Protection:
electronic
Multi-frequency dialling:
Are transferred the characteristics of BCA connected to the telephone line
Relay outputs characteristics:
Switching
voltage:
63Vac max
Switching
current
1Amax
Programmable contact closing time:
1s - 2s – 4s – 10s
Operational temperature:
5 ÷ 40°C
Relative humidity:
10 ÷ 90%
DIMENSIONS AND ASPECT CHARACTERISTICS
DIN modules
6
Plastic
fi
nishing:
satinized for all external surfaces (in ABS)
Weight:
about 330g
Colour:
Grey RAL 7038
The dimensions are:
Width:
105mm
Height:
65mm
Depth:
90mm
SUMMARIZING TABLE FOR PROGRAMMING
CODE FOR TELEPHONE LINE ENGAGEMENT
PARAMETER
VALUE
01
1
2
FUNCTION
0
9
TELEPHONE TYPE COMBIPHONE/BCA
PARAMETER
VALUE
02
1
2
FUNCTION
Combiphone
BCA
ATT1 RELAY ACTIVATION TIME
PARAMETER
VALUE
03
1
2
3
4
FUNCTION
1s
2s
4s
10s
ATT2 RELAY ACTIVATION TIME
PARAMETER
VALUE
04
1
2
3
4
FUNCTION
1s
2s
4s
10s
FLASH BUTTON (R) IDENTIFICATION TIME
PARAMETER
VALUE
05
1
2
3
4
5
FUNCTION
100ms
270ms
400ms
600ms
900ms
DOOR PHONE CALL DURATION
PARAMETER
VALUE
07
1
2
3
4
FUNCTION
5s
10s
20s
30s
COUNTRY OF USE
PARAMETER
VALUE
08
1
2
3
4
5
6
7
8
9
FUNCTION
Italy
France Belgium
Israel
Holland Ireland
Czech
Republic
Hungary
England
OPERATING MODE A/B
PARAMETER
VALUE
09
1
2
FUNCTION
A
B
CONFIRMATION TONE FOR A DOOR PHONE
PARAMETER
VALUE
10
1
2
FUNCTION
ON
OFF