54
DS1061-036A
The following parameters are configurable:
•
Phone options
:
o
Communicators
, where it is possible to indicate if in the control panel are installed the PSTN
telephone communicator, the GSM module or both of them. If both of them are installed, it is also
possible to select, with priority, which one must be used first.
o
Phone call check
, that allows to set the following parameters:
Answer control
, that recognizes the call signal, after the number has been dialled
.
If the
answer check is enabled, the communicator
waits until the called number answers, before
playing the alarm vocal message (if the call signal is not recognized, the alarm vocal
message is played anyway, after some seconds from the end of the dialled telephone
number). If disabled, the vocal message is played 2 seconds after the telephone number
has been dialled.
Tones control
,
if enabled, it dials the number only after the dial tone has been detected; if
disabled, it enters the number 3 seconds after the line has been seized. If the GSM
communicator is installed, it enables the field test before the calls cycle.
Incoming call rings
, that allows to set the rings number before the control panel answers
an incoming call. If the rings number is set to “0”, incoming calls are ignored.
•
Phone line test
tests, allows to select one of the following options
:
o
Disabled
, disables the test used to check the telephone line correct operation.
o
Enabled without SAG alarm
, enables the automatic test for telephone line check (failure or no
line). The test is performed each time the system is activated/deactivated (also partially). If the
test is unsuccessful, no tamper alarm is generated.
o
Enabled with SAG alarm
, enables the automatic test for telephone line check (failure or no line).
The test is performed each time the system is armed/disarmed (also partially). If the test is
unsuccessful, is generated not only the failure signalling, but also the tamper alarm.
•
Phone numbers
:
o
Phone number
, is the telephone number to be used. The number can be composed by 21 digits max.
o
Call type
, used to indicate if the alarm message must be sent only as vocal message (Voice), as
vocal and SMS (
Voice + SMS
) or numeric, if addressed to an alarm reception centre (IDP, ADF
or SIA, according to the protocol used by the alarm reception centre). SMS messages will be
sent only if the GSM module is present and has priority, and numeric calls to alarm reception
centres only if the PSTN module is present and has priority.
o
As last step, select the alarm events associated to the telephone number, that will generate the
alarm message sending.
Содержание 1061/006A
Страница 35: ...DS1061 036A 35 5 4 2 Main programming menu...
Страница 39: ...DS1061 036A 39 5 4 6 Times programming menu...
Страница 44: ...44 DS1061 036A 5 4 11 PSTN GSM communicator programming menu...
Страница 45: ...DS1061 036A 45...
Страница 63: ...DS1061 036A 63 9 EXAMPLE OF CONNECTION WITH NC LINES...