DS1061-036A
37
5.4.4
Outputs Programming Menu
Only the two auxiliary relay outputs 1 and 2 are programmable. The output configuration determines which
alarms will cause the relay contact switching (excited relay).
Possible associations are:
•
Burglar
alarm
: the relay switches (for the alarm time) when the control panel receives an
Burglar
alarm or a Tamper alarm.
•
Pre-alarm
: the relay switches when the input 1 is activated. The relay stays excited until the Entry
time is elapsed.
•
Technological alarm
: the relay switches (for the alarm time) when the control panel receives a
Technological alarm.
•
Emergency
alarm
:
the relay switches (for the alarm time) when the control panel receives a
Emergency
alarm.
•
Low battery/failure alarm
: the relay switches when occurs one of the following failures:
o
Low battery.
o
Failure on PSTN telephone line or no GSM network
o
Burnt fuse
.
o
Bus line failure
.
Failure signallings stay active until failure is removed.
To an output can be associated only one of the above mentioned alarms.