Front and Rear Panel Descriptions

Front Panel  

The front panel consists of 2 indicator lights illuminate when in use.

Power

: Illuminates when the power supply is connected to an outlet.

Ethernet

: Illuminates when connected to a Network Router. On=Connected, Off=Not Connected, Blinking =

attempting to connect.

Reset

: Press for one second and release button located under the MRX-10 to restart the unit. Pressing and

holding the reset button for 15 seconds will set the unit to factory default. 

Rear Panel  

The rear panel ports are:

Power

: Provides connection to included 12V/1Amp Power Supply.

LAN

: Provides connection to LAN (

Local Area network

) via RJ45 cable. This essential connection is responsible

for:

Programming

: Not only does the MRX-10 receive its programming over the network, it also issues

programming to connected remotes, keypads and touch panels through this port.

Communication

: During normal operation, remote controls (except the TRC-780), keypads and touchpanels

send commands to the MRX-10 through the LAN port. These commands are then relayed to a control port
(

IR, RS-232,relay or trigger

) on the local MRX-10, or to one of the “sub” controllers.

Содержание MRX-10

Страница 1: ...from the TRC 780 and returns status and metadata for true two way feedback All of the other remotes keypads and touch panels in the Total Control line take this communication to the next level by using IP over the local area network LAN For outgoing commands to connected devices the MRX 10 is equipped for anything Whether IR RS 232 relays triggers or sensors the MRX 10 can control virtually any de...

Страница 2: ...0 resulting in faster more efficient programming Although the MRX 10 works perfectly well in a single room installation the real power of the Total Control System comes when it is expanded to multiple rooms and controlling the subsystems in the home or commercial space Capable of extending its communication to other MRX 10s or MRX 1s acting as sub units each tethered controller becomes part of the s...

Страница 3: ... factory default Rear Panel The rear panel ports are Power Provides connection to included 12V 1Amp Power Supply LAN Provides connection to LAN Local Area network via RJ45 cable This essential connection is responsible for Programming Not only does the MRX 10 receive its programming over the network it also issues programming to connected remotes keypads and touch panels through this port Communic...

Страница 4: ...ted only to its dedicated IR output and emitter preventing IR splash from multiple emitters flashing at the same time Relay NO NC COM Provides configurable switch closure control Sensors Provides connection to up to four URC Voltage Sensors VS 1006 or URC Video Sensors VID 6 for status readings in sensor based macros 12V Output Two programmable 12V 0 2A outputs Each may be programmed to turn on off o...

Страница 5: ...nected to the detachable connectors for use of the relays Network Installation 1 Connect an Ethernet cable RJ45 to the rear of the MRX 10 and into the network router or switch 2 Connect your laptop into the same network router as the MRX 10 3 Plug flashers into any of the eight flasher ports on the rear of the MRX 10 Locating the MAC Address The network MAC Address is a unique number that identifies ...

Страница 6: ... sluggish operation check that the remote control is set to a particular LINE OUT rather than ALL When IR commands are sent to all the flashers in a cabinet you can have difficulty adjusting the IR Output Reprogram the remote control to send IR commands only via a specific 1 8 Line Output then readjust the IR Line Output level 1 Connect an IR emitter to each IR output and run the emitter wire to the f...

Страница 7: ...rial commands to be triggered from a Total Control remote and sent from the MRX 10 over the network connection The signal is then sent to the device over proprietary URC RS 232 cables These use either male or female DB 9 connections with standard pin outs Programming is done in the Accelerator software ...

Страница 8: ...the MRX 10 The MRX 10 can use either a Video composite or Voltage signal to determine the power status of the equipment it controls This can then be used to alter the function of a Macro by using IF ELSE statements in the programming software Using a VID 1 Video Sensor cable the MRX 10 can detect a video signal from a Composite or Component video output The VS 100 Voltage Sensor will detect a Volt...

Страница 9: ... current to an electrical switch or motor for use with screens blinds curtains etc The Relay can be used as either a latching contact or a momentary contact depending on the programming The command to actuate the Relay is programmed using the Accelerator software and is sent from the MRX 10 when triggered by any Total Control system remote ...

Страница 10: ...Application Diagram 72 ...

Страница 11: ...he MRX 10 or MRX 1 Using URC Accelerator programming software a Macro can be programmed to react to the status of this sensor VS 1006 This voltage sensor cable is designed to connect to a sensor port on the MRX 10 or MRX 1 Using URC Accelerator programming software a Macro can be programmed to react to the status of this sensor RS232M RS232F Available with either male or female RS 232 connectors t...