Electrical Connection
WARNING: This fireplace must be electrically
connected and grounded in accordance with local
codes or, in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code Part 1,
Safety Standards For Electrical Installations, or The
National Electrical Code ANSI / NFPA 70 in the US.
Electrical Requirements:
120VAC. Appliance receptacle must be hard wired with
coated 14/2 AWG (minimum) copper electrical wire such as
Lumex or Romex. Consult your electrical code for further
details. Wire your unit as follows:
1.
Run wire to left rear of unit (see
below); be sure wire is NOT live.
2.
Remove left side and front screen. Remove lower
bezel and locate the electrical junction box.
Fireplace Leveling
NOTES:
1: It is essential to level the unit from proper operation.
2: This step is not necessary when wall mounting unit.
All Urbana units come with leveling feet to accommodate
uneven surfaces. The leveling feet can also be used to
raise the height of the fireplace up an additional 1" (25
mm). Ensure the fireplace is in its final position before
proceeding.
Leveling feet come fully inserted; you will need to
unscrew the feet to see any adjustment (no lock nut used).
Adjust as follows:
1.
Use a level on the top of the unit to
determine which feet need adjustment.
2.
Use a 9/16 wrench to unscrew the feet
to make the necessary adjustments.
3.
Verify fireplace is level in all 3 planes.